Solid implantable devices for sustained drug delivery Magill, Elizabeth; Demartis, Sara; Gavini, Elisabetta ...
Advanced drug delivery reviews,
August 2023, 2023-Aug, 2023-08-00, 20230801, Letnik:
199
Journal Article
Recenzirano
Odprti dostop
Display omitted
Implantable drug delivery systems (IDDS) are an attractive alternative to conventional drug administration routes. Oral and injectable drug administration are the most common routes ...for drug delivery providing peaks of drug concentrations in blood after administration followed by concentration decay after a few hours. Therefore, constant drug administration is required to keep drug levels within the therapeutic window of the drug. Moreover, oral drug delivery presents alternative challenges due to drug degradation within the gastrointestinal tract or first pass metabolism. IDDS can be used to provide sustained drug delivery for prolonged periods of time. The use of this type of systems is especially interesting for the treatment of chronic conditions where patient adherence to conventional treatments can be challenging. These systems are normally used for systemic drug delivery. However, IDDS can be used for localised administration to maximise the amount of drug delivered within the active site while reducing systemic exposure. This review will cover current applications of IDDS focusing on the materials used to prepare this type of systems and the main therapeutic areas of application.
Small-scale soft-bodied machines that respond to externally applied magnetic field have attracted wide research interest because of their unique capabilities and promising potential in a variety of ...fields, especially for biomedical applications. When the size of such machines approach the sub-millimeter scale, their designs and functionalities are severely constrained by the available fabrication methods, which only work with limited materials, geometries, and magnetization profiles. To free such constraints, here, we propose a bottom-up assembly-based 3D microfabrication approach to create complex 3D miniature wireless magnetic soft machines at the milli- and sub-millimeter scale with arbitrary multimaterial compositions, arbitrary 3D geometries, and arbitrary programmable 3D magnetization profiles at high spatial resolution. This approach helps us concurrently realize diverse characteristics on the machines, including programmable shape morphing, negative Poisson's ratio, complex stiffness distribution, directional joint bending, and remagnetization for shape reconfiguration. It enlarges the design space and enables biomedical device-related functionalities that are previously difficult to achieve, including peristaltic pumping of biological fluids and transport of solid objects, active targeted cargo transport and delivery, liquid biopsy, and reversible surface anchoring in tortuous tubular environments withstanding fluid flows, all at the sub-millimeter scale. This work improves the achievable complexity of 3D magnetic soft machines and boosts their future capabilities for applications in robotics and biomedical engineering.
Intrathecal drug infusion therapy is usually considered when spinal-acting analgesics or antispasmodics administered via the oral or transdermal routes fail to control patients' pain or are ...associated with unacceptable side effects. The intrathecal administration of centrally acting agents bypasses the blood-brain-barrier resulting in much higher cerebrospinal fluid (CSF) concentrations while using reduced amounts of medication to achieve equipotent doses. The intrathecal approach is associated with higher rates of satisfactory pain relief and lower rates of treatment failures and technical complications compared to the epidural route. A paucity of randomized controlled trials (RCTs) has led to concern regarding proper use, selection criteria, and safety of these devices. Cost effectiveness and comparative therapies have now also become a focus of discussion.
The purpose of this systematic review is to evaluate and update the available evidence for the efficacy and safety of intrathecal infusions used in long-term management (> 6 months) of chronic pain. This paper will not focus on intrathecal administration for spasticity or movement disorders.
A systematic review of intrathecal infusion through implanted drug delivery devices for chronic pain.
Literature search through EMBASE, Medline, Cochrane databases, and systematic reviews as well as peer-reviewed non-indexed journals from 1980 to December 2010. Studies are assessed using the Agency for Healthcare Research and Quality (AHRQ) criteria for observational studies and the Cochrane Musculoskeletal Review Group criteria for randomized trials. The level of evidence was determined using 5 levels of evidence, ranging from Level I to III with 3 subcategories in Level II, based on the quality of evidence developed by the U.S. Preventive Services Task Force (USPSTF).
The primary outcome measure for chronic non-cancer is pain relief (short-term relief ≤ one-year and long-term > one-year), whereas it is 3 months for cancer. Secondary outcome measures of improvement in functional status, psychological status, return to work, and reduction in opioid intake.
The level of evidence for this systematic review of non-cancer pain studies meeting the inclusion criteria of continuous use of an intrathecal drug delivery system (IDDS) for at least 12 months duration with at least 25 patients in the cohort, is Level II-3 based on USPSTF criteria. The level of evidence for this systemic review for cancer-related pain studies meeting the inclusion criteria of continuous use of IDDS for at least 3 months duration with at least 25 patients in the cohort is Level II-2 based on USPSTF criteria.
Based on the available evidence, the recommendation for intrathecal infusion systems for cancer-related pain is moderate recommendation based on the high quality of evidence and the recommendation is limited to moderate based on the moderate quality of evidence from non-randomized studies for non-cancer related pain.
The achievement of glycaemic control remains challenging for patients with type 1 diabetes. We assessed the effectiveness of day-and-night hybrid closed-loop insulin delivery compared with ...sensor-augmented pump therapy in people with suboptimally controlled type 1 diabetes aged 6 years and older.
In this open-label, multicentre, multinational, single-period, parallel randomised controlled trial, participants were recruited from diabetes outpatient clinics at four hospitals in the UK and two centres in the USA. We randomly assigned participants with type 1 diabetes aged 6 years and older treated with insulin pump and with suboptimal glycaemic control (glycated haemoglobin HbA1c 7·5–10·0%) to receive either hybrid closed-loop therapy or sensor-augmented pump therapy over 12 weeks of free living. Training on study insulin pump and continuous glucose monitoring took place over a 4-week run-in period. Eligible subjects were randomly assigned using central randomisation software. Allocation to the two study groups was unblinded, and randomisation was stratified within centre by low (<8·5%) or high (≥8·5%) HbA1c. The primary endpoint was the proportion of time that glucose concentration was within the target range of 3·9–10·0 mmol/L at 12 weeks post randomisation. Analyses of primary outcome and safety measures were done in all randomised patients. The trial is registered with ClinicalTrials.gov, number NCT02523131, and is closed to accrual.
From May 12, 2016, to Nov 17, 2017, 114 individuals were screened, and 86 eligible patients were randomly assigned to receive hybrid closed-loop therapy (n=46) or sensor-augmented pump therapy (n=40; control group). The proportion of time that glucose concentration was within the target range was significantly higher in the closed-loop group (65%, SD 8) compared with the control group (54%, SD 9; mean difference in change 10·8 percentage points, 95% CI 8·2 to 13·5; p<0·0001). In the closed-loop group, HbA1c was reduced from a screening value of 8·3% (SD 0·6) to 8·0% (SD 0·6) after the 4-week run-in, and to 7·4% (SD 0·6) after the 12-week intervention period. In the control group, the HbA1c values were 8·2% (SD 0·5) at screening, 7·8% (SD 0·6) after run-in, and 7·7% (SD 0·5) after intervention; reductions in HbA1c percentages were significantly greater in the closed-loop group compared with the control group (mean difference in change 0·36%, 95% CI 0·19 to 0·53; p<0·0001). The time spent with glucose concentrations below 3·9 mmol/L (mean difference in change −0·83 percentage points, −1·40 to −0·16; p=0·0013) and above 10·0 mmol/L (mean difference in change −10·3 percentage points, −13·2 to −7·5; p<0·0001) was shorter in the closed-loop group than the control group. The coefficient of variation of sensor-measured glucose was not different between interventions (mean difference in change −0·4%, 95% CI −1·4% to 0·7%; p=0·50). Similarly, total daily insulin dose was not different (mean difference in change 0·031 U/kg per day, 95% CI −0·005 to 0·067; p=0·09) and bodyweight did not differ (mean difference in change 0·68 kg, 95% CI −0·34 to 1·69; p=0·19). No severe hypoglycaemia occurred. One diabetic ketoacidosis occurred in the closed-loop group due to infusion set failure. Two participants in each study group had significant hyperglycaemia, and there were 13 other adverse events in the closed-loop group and three in the control group.
Hybrid closed-loop insulin delivery improves glucose control while reducing the risk of hypoglycaemia across a wide age range in patients with suboptimally controlled type 1 diabetes.
JDRF, NIHR, and Wellcome Trust.
Trials of GDNF in Parkinson's disease have yielded inconsistent results. In a randomised controlled trial, Whone et al. administer GDNF using a paradigm designed to optimize delivery to the putamen. ...18FDOPA PET reveals putamen-wide uptake, but GDNF does not differ from placebo in its effects on motor function.
Abstract
We investigated the effects of glial cell line-derived neurotrophic factor (GDNF) in Parkinson's disease, using intermittent intraputamenal convection-enhanced delivery via a skull-mounted transcutaneous port as a novel administration paradigm to potentially afford putamen-wide therapeutic delivery. This was a single-centre, randomized, double-blind, placebo-controlled trial. Patients were 35-75 years old, had motor symptoms for 5 or more years, and presented with moderate disease severity in the OFF state Hoehn and Yahr stage 2-3 and Unified Parkinson's Disease Rating Scale motor score (part III) (UPDRS-III) between 25 and 45 and motor fluctuations. Drug delivery devices were implanted and putamenal volume coverage was required to exceed a predefined threshold at a test infusion prior to randomization. Six pilot stage patients (randomization 2:1) and 35 primary stage patients (randomization 1:1) received bilateral intraputamenal infusions of GDNF (120 µg per putamen) or placebo every 4 weeks for 40 weeks. Efficacy analyses were based on the intention-to-treat principle and included all patients randomized. The primary outcome was the percentage change from baseline to Week 40 in the OFF state (UPDRS-III). The primary analysis was limited to primary stage patients, while further analyses included all patients from both study stages. The mean OFF state UPDRS motor score decreased by 17.3 ± 17.6% in the active group and 11.8 ± 15.8% in the placebo group (least squares mean difference: −4.9%, 95% CI: −16.9, 7.1, P = 0.41). Secondary endpoints did not show significant differences between the groups either. A post hoc analysis found nine (43%) patients in the active group but no placebo patients with a large clinically important motor improvement (≥10 points) in the OFF state (P = 0.0008). 18F-DOPA PET imaging demonstrated a significantly increased uptake throughout the putamen only in the active group, ranging from 25% (left anterior putamen; P = 0.0009) to 100% (both posterior putamina; P < 0.0001). GDNF appeared to be well tolerated and safe, and no drug-related serious adverse events were reported. The study did not meet its primary endpoint. 18F-DOPA imaging, however, suggested that intermittent convection-enhanced delivery of GDNF produced a putamen-wide tissue engagement effect, overcoming prior delivery limitations. Potential reasons for not proving clinical benefit at 40 weeks are discussed.
A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes.
In a 16-week, multicenter, randomized, open-label, ...parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring.
A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points equivalent to 2.6 hours per day; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group.
In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).
Due to an increase in implantable device-related anesthesia pain medicine claims, the authors investigated anesthesia liability associated with these devices.
After institutional review board ...approval, the authors identified 148 pain medicine device claims from 1990 or later in the Anesthesia Closed Claims Project Database. Device-related damaging events included medication administration events, infections, hematomas, retained catheter fragments, cerebrospinal fluid leaks, cord or cauda equina trauma, device placed at wrong level, stimulator incorrectly programmed, delay in recognition of granuloma formation, and other issues.
The most common devices were implantable drug delivery systems (IDDS; 64%) and spinal cord stimulators (29%). Device-related care consisted of surgical device procedures (n = 107) and IDDS maintenance (n = 41). Severity of injury was greater in IDDS maintenance claims (56% death or severe permanent injury) than in surgical device procedures (26%, P < 0.001). Death and brain damage in IDDS maintenance claims resulted from medication administration errors (n = 13; 32%); spinal cord injury resulted from delayed recognition of granuloma formation (n = 9; 22%). The most common damaging events for surgical device procedures were infections, inadequate pain relief, cord trauma, retained catheter fragments, and subcutaneous hygroma. Care was more commonly assessed as less than appropriate (78%) and payments more common (63%) in IDDS maintenance than in surgical device procedure claims (P < 0.001).
Half of IDDS maintenance claims were associated with death or permanent severe injury, most commonly from medication errors or failure to recognize progressive neurologic deterioration. Practitioners implanting or managing devices for chronic pain should exercise caution in these areas to minimize patient harm.
The feasibility, safety, and efficacy of prolonged use of an artificial beta cell (closed-loop insulin-delivery system) in the home setting have not been established.
In two multicenter, crossover, ...randomized, controlled studies conducted under free-living home conditions, we compared closed-loop insulin delivery with sensor-augmented pump therapy in 58 patients with type 1 diabetes. The closed-loop system was used day and night by 33 adults and overnight by 25 children and adolescents. Participants used the closed-loop system for a 12-week period and sensor-augmented pump therapy (control) for a similar period. The primary end point was the proportion of time that the glucose level was between 70 mg and 180 mg per deciliter for adults and between 70 mg and 145 mg per deciliter for children and adolescents.
Among adults, the proportion of time that the glucose level was in the target range was 11.0 percentage points (95% confidence interval CI, 8.1 to 13.8) greater with the use of the closed-loop system day and night than with control therapy (P<0.001). The mean glucose level was lower during the closed-loop phase than during the control phase (difference, -11 mg per deciliter; 95% CI, -17 to -6; P<0.001), as were the area under the curve for the period when the glucose level was less than 63 mg per deciliter (39% lower; 95% CI, 24 to 51; P<0.001) and the mean glycated hemoglobin level (difference, -0.3%; 95% CI, -0.5 to -0.1; P=0.002). Among children and adolescents, the proportion of time with the nighttime glucose level in the target range was higher during the closed-loop phase than during the control phase (by 24.7 percentage points; 95% CI, 20.6 to 28.7; P<0.001), and the mean nighttime glucose level was lower (difference, -29 mg per deciliter; 95% CI, -39 to -20; P<0.001). The area under the curve for the period in which the day-and-night glucose levels were less than 63 mg per deciliter was lower by 42% (95% CI, 4 to 65; P=0.03). Three severe hypoglycemic episodes occurred during the closed-loop phase when the closed-loop system was not in use.
Among patients with type 1 diabetes, 12-week use of a closed-loop system, as compared with sensor-augmented pump therapy, improved glucose control, reduced hypoglycemia, and, in adults, resulted in a lower glycated hemoglobin level. (Funded by the JDRF and others; AP@home04 and APCam08 ClinicalTrials.gov numbers, NCT01961622 and NCT01778348.).
Biofuel cells that generate electricity from glucose in blood are promising for powering implantable biomedical devices. Immobilizing interconnected enzyme and redox mediator in a highly conducting, ...porous electrode maximizes their interaction with the electrolyte and minimizes diffusion distances for fuel and oxidant, thereby enhancing power density. Here we report that our separator-free carbon nanotube yarn biofuel cells provide an open-circuit voltage of 0.70 V, and a maximum areal power density of 2.18 mW cm(-2) that is three times higher than for previous carbon nanotube yarn biofuel cells. Biofuel cell operation in human serum provides high areal power output, as well as markedly increased lifetime (83% remained after 24 h), compared with previous unprotected biofuel cells. Our biscrolled yarn biofuel cells are woven into textiles having the mechanical robustness needed for implantation for glucose energy harvesting.