Introduction Cytomegalovirus (CMV) infection remains a challenge following kidney transplantation (KTx). Currently, CMV-IgG serostatus at transplantation is used to individualize CMV preventive ...strategies. We assessed the clinical utility of CMV-IGRA for predicting CMV infection following KTx. Methods We performed a nationwide prospective cohort study from August 2016 until December 2022. Data from all adult KTx recipients in Norway, n=1,546 (R+; n=1,157, D+/R-; n=260, D-/R-; 129), were included with a total of 3,556 CMV-IGRA analyses (1,375 at KTx, 1,188 at eight weeks, 993 one-year after KTx) and 35,782 CMV DNAemia analyses. Results In R+ recipients CMV-IGRA status, measured at any of the time-points, could not identify any differential risk of later CMV infection. D+/R- recipients remaining CMV-IGRA negative 1-year after transplantation (regardless of positive CMV DNAemia and/or CMV IgG status at that time) had increased risk of developing later CMV infection compared to D+/R- recipients who had become CMV-IGRA positive (14% vs. 2%, p=0.01). Conclusion Knowledge of pre-transplant CMV-IGRA status did not provide additional information to CMV-IgG serostatus that could improve current post-transplant CMV treatment algorithms. However, D+/R- recipients with a persisting negative CMV-IGRA one-year after transplantation remained at increased risk of experiencing later CMV infection. Therefore we advocate post-transplant CMV-IGRA monitoring in these patients.
The QuantiFERON-TB Gold plus (QFT-Plus) assay, an interferon gamma (IFN-γ) release assay (IGRA), was recently introduced as the next version of the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay for ...diagnosing latent tuberculosis (TB). Whereas the QFT-GIT assay uses only one TB tube that induces a cell-mediated immune (CMI) response of CD4
T cells, the QFT-Plus has an additional TB antigen 2 tube (TB2) for the CMI response of CD8
T and CD4
T cells, in addition to a TB antigen 1 (TB1) tube for the CMI response of CD4
T cells only. We compared the results of the QFT-Plus and QFT-GIT assays as routine clinical tests for diagnosing TB. Samples from 220 patients referred for routine IGRA in various clinical departments were used. Correlations between IFN-γ levels in the QFT-GIT and QFT-Plus assays were strong and showed good agreement (kappa value = 0.69). Seven cases with positive QFT-GIT assay results and negative QFT-Plus assay results showed IFN-γ values near the cutoff value. However, 10 cases with active TB, recent TB, or immune problems showed discordance with the positive results only in the TB2 tube in QFT-Plus, unlike the negative results in TB1 and TB tubes. In these cases, IFN-γ levels in the TB2 tube were significantly higher than those in other tubes. This is the first study to compare these assays as routine IGRAs in the clinical setting. The QFT-Plus assay showed good agreement with the QFT-GIT assay and is presumably advantageous for patients with active TB, recent TB, and specific immune conditions involving CD8
T-cell responses.
•Whole-blood interferon-γ-release assay (IGRA) enabled the response to SARS-CoV-2 peptides to be evaluated.•Spike protein was the best stimulus to discriminate COVID-19 from NO-COVID-19.•A ...SARS-CoV-2-specific response is rarely observed in NO-COVID-19 individuals.•This SARS-CoV-2 IGRA has the potential to be a powerful diagnostic tool.
To identify the best experimental approach to detect a SARS-CoV-2-specific T cell response using a whole-blood platform.
Whole-blood from 56 COVID-19 and 23 “NO-COVID-19” individuals were stimulated overnight with different concentrations (0.1 or 1 μg/mL) of SARS-CoV-2 PepTivator® Peptide Pools, including spike (pool S), nucleocapsid (pool N), membrane (pool M), and a MegaPool (MP) of these three peptide pools. ELISA was used to analyse interferon (IFN)-γ levels.
The IFN-γ-response to every SARS-CoV-2 peptide pool was significantly increased in COVID-19 patients compared with NO-COVID-19 individuals. Pool S and MegaPool were the most potent immunogenic stimuli (median: 0.51, IQR: 0.14–2.17; and median: 1.18, IQR: 0.27–4.72, respectively) compared with pools N and M (median: 0.22, IQR: 0.032–1.26; and median: 0.22, IQR: 0.01−0.71, respectively). The whole-blood test based on pool S and MegaPool showed a good sensitivity of 77% and a high specificity of 96%. The IFN-γ-response was mediated by both CD4+ and CD8+ T cells, and independently detected of clinical parameters in both hospitalized and recovered patients.
This easy-to-use assay for detecting SARS-CoV-2-specific T cell responses may be implemented in clinical laboratories as a powerful diagnostic tool.
In sepsis, personalized immunotherapy is being evaluated as a means of restoring immune function in the most severely affected patients. Biomarkers play a crucial role in this process, as there are ...no clear clinical indicators of immune dysfunction. Functional testing is considered a gold standard for assessing immune function, but this approach faces analytical challenges in terms of clinical implementation. The use of technician-dependent, time-consuming, home-made protocols often leads to poor standardization. This study represents the first beta testing of a fully automated interferon-γ release assay (IGRA) for monitoring the functionality of antigen-independent T lymphocytes. We observed a significant decrease in IFN-γ release capacity, which was associated with typical alterations in immunological cellular parameters (such as low mHLA-DR expression and decreased CD8 T lymphocyte count), in 22 patients with septic shock. Since the test is performed using whole blood and requires no technician intervention, with results available within 4 h, it may offer new possibilities for monitoring patients with immune alterations in routine clinical conditions. Further investigations in larger cohorts of patients are now needed to validate its clinical potential.
The fourth-generation QuantiFERON test for tuberculosis infection, QuantiFERON-TB Gold Plus (QFT-Plus) has replaced the earlier version, QuantiFERON-TB Gold In-Tube (QFT-GIT). A clinical need exists ...for information about agreement between QFT-Plus and other tests. We conducted this study to assess agreement of test results for QFT-Plus with those of QuantiFERON-TB Gold In-Tube (QFT-GIT), T-SPOT.TB (T-SPOT), and the tuberculin skin test (TST). Persons at high risk of latent tuberculosis infection (LTBI) and/or progression to tuberculosis (TB) disease were enrolled at the 10 sites of the Tuberculosis Epidemiologic Studies Consortium from October 2016 through May 2017; each participant received all four tests. Cohen's kappa (κ) and Wilcoxon signed-rank test compared qualitative and quantitative results of QFT-Plus with the other tests. Test results for 506 participants showed 94% agreement between QFT-Plus and QFT-GIT, with 19% positive and 75% negative results. When the tests disagreed, it was most often in the direction of QFT-GIT negative/QFT-Plus positive. QFT-Plus had similar concordance as QFT-GIT with TST (77% and 77%, respectively) and T-SPOT (92% and 91%, respectively). The study showed high agreement between QFT-GIT and QFT-Plus in a direct comparison. Both tests had similar agreement with TST and T-SPOT.
The diagnosis of latent tuberculosis (TB) infection (LTBI) is critical to improve TB treatment and control, and the T-SPOT.TB test is a commercial enzyme-linked immunosorbent spot assay used for this ...purpose. The objective of the study was to increase automation and extend the time between blood collection and processing for the T-SPOT.TB test from 0 to 8 h to 0 to 54 h. The previous maximum time between blood collection and processing for the T-SPOT.TB test is 32 h using T-Cell Xtend. For this, we compared the T-SPOT.TB test using manual peripheral blood mononuclear cell (PBMC) isolation by density gradient separation at 0 to 8 h (reference method, control arm) to an automated PBMC isolation method using magnetic beads (T-Cell Select kit) at 0 to 55 h postcollection. A total of 620 subjects were enrolled from 4 study sites, and blood samples were collected from each volunteer, comprising 1,850 paired samples in total. Overall agreement between both methods was 96.8% (confidence interval CI, 95.9 to 97.6%), with 95.8% (CI, 93.5 to 97.5%) positive and 97.1% negative agreement (CI, 96.1 to 97.9%). In summary, there was a strong overall agreement between the automated and manual T-SPOT.TB test processing methods. The results suggest that the T-SPOT.TB test can be processed using automated positive selection with magnetic beads using T-Cell Select to decrease hands-on time. Also, this cell isolation method allowed for the time between blood collection and processing to range from 0 to 55 h. Additional studies in larger and diverse patient populations including immunocompromised and pediatric patients are needed.
The QuantiFERON-TB Gold Plus (QFT-Plus) was introduced in 2015 as a new generation of interferon-gamma release assays (IGRAs) designed to detect Mycobacterium tuberculosis infection (TB). Examination ...of its diagnostic accuracy is crucial before it is launched in Japan.
We examined 99 patients with laboratory-confirmed active TB (patients) and 117 healthy volunteers with no risk of TB infection (controls) at a medical center in Tokyo, Japan. Blood samples were collected from both the patients and controls and tested using three types of IGRAs: the QFT-Plus, the QuantiFERON-TB Gold In-Tube (QFT-GIT), and the T-SPOT.TB (T-SPOT). The sensitivity and specificity of each IGRA were examined and compared.
The sensitivity of the QFT-Plus was 98.9% (95% confidence interval CI, 0.934–0.998) and similar to that of the QFT-GIT (97.9%; 95% CI, 0.929–0.998) and T-SPOT (96.9%; 95% CI, 0.914–0.994). The specificity of the QFT-Plus was the same as that of the QFT-GIT and T-SPOT (98.1%; 95% CI, 0.934–0.998). One patient with uncontrolled diabetes mellitus showed negative results on all three IGRAs.
The QFT-Plus showed a high degree of agreement with the QFT-GIT and T-SPOT, with high sensitivity and specificity. Severe diabetes mellitus may influence the results of IGRAs. Larger studies are needed to validate the accuracy of the GFT-Plus and determine whether it can contribute as adjunctive method for the early diagnosis of active TB in Japan.
We established a set of atmospheric standard temperature and water vapor profiles and examined the characteristics of the tropopause over the Tibetan Plateau in summer using IGRA, COSMIC and ERA-5 ...datasets. We studied the temperature and water vapor profiles under clear sky, cloudy and “other” conditions and their diurnal variation. The atmosphere over the Central Tibetan Plateau is warmest and wettest in the lower to mid-troposphere, whereas the Western Tibetan Plateau is warmest and driest in the mid to high troposphere. The coldest and wettest air near the tropopause is over the Eastern Tibetan Plateau. The height of the tropopause decreases gradually from west to east over the plateau, although the difference in height is ≤0.5 km. Relative to clear sky conditions, cloudy conditions are characterized by warming and wetting anomalies in the lower to mid-troposphere and cooling and wetting anomalies in the tropopause and lower stratosphere. The largest vertical diurnal differences in temperature are at the surface and the difference decreases with increasing altitude from the surface to ~12 km. The difference between the six time periods of early morning, morning, noon, afternoon, evening and midnight are within −0.5 to 0.5 K above 12 km. The difference in water vapor between the six time periods is ≤0.2 g m−3. The lowest tropopause is at early morning. The height of the tropopause then increases followed by a decrease, with a sharp peak at noon. This establishment of a set of atmospheric standard profiles over Tibetan Plateau provides more accurate inputs for climate models.
•This establishment of a set of atmospheric standard profiles provides more accurate inputs for climate models.•We examine the differences of temperature and water vapor profiles between clear sky, cloudy and “other” conditions.•The characteristics for diurnal variation of temperature and water vapor profiles over Tibetan Plateau are quantified.•The height and temperature of tropopause under clear sky and cloudy conditions and their diurnal variations are revealed.
QuantiFERON-TB Gold Plus (QFT-Plus) is a new-generation QuantiFERON-TB Gold In-Tube (QFT-GIT) assay which has two antigen-coated tubes called TB1, which contains long peptides derived from ESAT-6 and ...CFP-10, and TB2, which contains the same components as TB1 and additional short peptides which potentially stimulate CD8
T cells through the presentation of major histocompatibility complex class I. This is the first study to compare QFT-Plus and QFT-GIT for use in the diagnosis of latent tuberculosis infection (LTBI) among immunocompromised patients in the Republic of Korea. Among 317 consecutive patients who underwent screening for LTBI before solid organ or hematopoietic stem cell transplantation and tumor necrosis factor alpha inhibitor treatment, LTBI was identified in 92 (29.0%) and 88 (27.8%) patients by QFT-GIT and QFT-Plus, respectively. The rate of concordance between QFT-GIT and QFT-Plus was 93.7% (κ value, 0.860), and the indeterminate rate (3.2%) was similar between QFT-GIT and QFT-Plus. Of 20 (6.3%) samples with discordant results, 11 (55.0%) and 7 (35.0%) were positive by QFT-GIT alone and QFT-Plus alone, respectively, and 2 (15.0%) were indeterminate by each assay. The interferon gamma level in samples with discordant results ranged from 0.39 to 1.10 IU/ml, except for one sample, in which the gamma interferon level was 2.97 IU/ml only in TB2. Conclusively, there was a high degree of agreement between the results of QFT-GIT and QFT-Plus for the screening of immunocompromised patients for LTBI. The reactivity in TB2 contributed substantially to the difference between QFT-GIT and QFT-Plus, particularly in solid organ transplant candidates. The significance of the discrete responses in TB1 and TB2 of QFT-Plus needs to be explored further by means of an immunological and clinical approach in different patient groups and clinical settings.
Despite the availability of effective treatment regimens for cutaneous tuberculosis, challenges to disease control result from delayed diagnosis, infection with multidrug-resistant mycobacterial ...strains, and coinfection with HIV. Delayed diagnosis can be mitigated when dermatologists are sensitized to the clinical signs and symptoms of infection and by the incorporation of appropriate diagnostic tests. All cases of cutaneous tuberculosis should be confirmed with histopathology and culture with or without molecular testing. In each case, a thorough evaluation for systemic involvement is necessary. Mycobacteria may not be isolated from cutaneous tuberculosis lesions and therefore, a trial of antituberculosis treatment may be required to confirm the diagnosis. The second article in this 2-part continuing medical education series describes the sequelae, histopathology, and treatment of tuberculosis.