NUK - logo
E-viri
  • Green, Mark A; Mathias, Carla J; Fletcher, James W

    Applied radiation and isotopes 116
    Journal Article

    (68)GaGa-DOTA-NOC was produced under an Expanded Access IND for 174 clinical PET/CT studies to evaluate patients with neuroendocrine tumors. Production employed either the TiO2-based Eckert & Ziegler (EZAG) (68)Ge/(68)Ga-generator (with fractionated elution), or the SiO2-based ITG (68)Ge/(68)Ga-generator. In both cases, (68)GaGa-DOTA-NOC was reliably produced, without pre-synthesis purification of the(68)Ga generator eluate, using readily-implemented manual synthesis procedures. (68)GaGa-DOTA-NOC radiochemical purity averaged 99.2±0.4%. Administered (68)Ga dose averaged 181±22 MBq, and administered peptide mass averaged 43.2±5.2µg (n=47) and 23.9±5.7µg (n=127), respectively, using the EZAG and ITG generators. At dose expiration, (68)Ge breakthrough in the final product averaged 2.7×10(-7)% and 5.4×10(-5%) using the EZAG and ITG generators, respectively.