Tachibana, Hidenobu; Watanabe, Yusuke; Kurokawa, Shogo; Maeyama, Takuya; Hiroki, Tomoyuki; Ikoma, Hideaki; Hirashima, Hideaki; Kojima, Hironori; Shiinoki, Takehiro; Tanimoto, Yuuki; Shimizu, Hidetoshi; Shishido, Hiroki; Oka, Yoshitaka; Hirose, Taka-Aki; Kinjo, Masashi; Morozumi, Takuya; Kurooka, Masahiko; Suzuki, Hidekazu; Saito, Tomohiko; Fujita, Keiichi; Shirata, Ryosuke; Inada, Ryuji; Yada, Ryuichi; Yamashita, Mikiko; Kondo, Kazuto; Hanada, Takashi; Takenaka, Tadashi; Usui, Keisuke; Okamoto, Hiroyuki; Asakura, Hiroshi; Notake, Ryoichi; Kojima, Toru; Kumazaki, Yu; Hatanaka, Shogo; Kikumura, Riki; Nakajima, Masaru; Nakada, Ryosei; Suzuki, Ryusuke; Mizuno, Hideyuki; Kawamura, Shinji; Nakamura, Mistuhiro; Akimoto, Tetsuo
Brachytherapy, 2022 Nov-Dec, Letnik: 21, Številka: 6Journal Article
To quantify dose delivery errors for high-dose-rate image-guided brachytherapy (HDR-IGBT) using an independent end-to-end dose delivery quality assurance test at multiple institutions. The novelty of our study is that this is the first multi-institutional end-to-end dose delivery study in the world. The postal audit used a polymer gel dosimeter in a cylindrical acrylic container for the afterloading system. Image acquisition using computed tomography, treatment planning, and irradiation were performed at each institution. Dose distribution comparison between the plan and gel measurement was performed. The percentage of pixels satisfying the absolute-dose gamma criterion was reviewed. Thirty-five institutions participated in this study. The dose uncertainty was 3.6% ± 2.3% (mean ± 1.96σ). The geometric uncertainty with a coverage factor of k = 2 was 3.5 mm. The tolerance level was set to the gamma passing rate of 95% with the agreement criterion of 5% (global)/3 mm, which was determined from the uncertainty estimation. The percentage of pixels satisfying the gamma criterion was 90.4% ± 32.2% (mean ± 1.96σ). Sixty-six percent (23/35) of the institutions passed the verification. Of the institutions that failed the verification, 75% (9/12) had incorrect inputs of the offset between the catheter tip and indexer length in treatment planning and 17% (2/12) had incorrect catheter reconstruction in treatment planning. The methodology should be useful for comprehensively checking the accuracy of HDR-IGBT dose delivery and credentialing clinical studies. The results of our study highlight the high risk of large source positional errors while delivering dose for HDR-IGBT in clinical practices.
Avtor
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.