E-viri
Recenzirano
-
Karcioglu, Amanda Silver; Trinh, Lily N.; Mcllroy, Dioan; Okose, Okenwa C.; Wang, Bo; Behr, Ian J.; Cheung, Anthony Y.; Srikanthan, Adithya; Russell, Marika D.; Kamani, Dipti; Abdelhamid Ahmed, Amr H.; Randolph, Gregory W.
Head & neck, August 2024, Letnik: 46, Številka: 8Journal Article
Objective Endotracheal tube (ETT) surface electrodes are used to monitor the vagus nerve (VN), recurrent laryngeal nerve (RLN), and external branch of the superior laryngeal nerve (EBSLN) during thyroid and parathyroid surgery. Alternative nerve monitoring methods are desirable when intubation under general anesthesia is not desirable or possible. In this pilot study, we compared the performance of standard ETT electrodes to four different noninvasive cutaneous recording electrode types (two adhesive electrodes and two needle electrodes) in three different orientations. Methods The VN was stimulated directly during thyroid and parathyroid surgery using a Prass stimulator probe. Electromyographic (EMG) responses for each patient were recorded using an ETT plus one of the following four cutaneous electrode types: large‐foot adhesive, small‐foot adhesive, long‐needle and short‐needle. Each of the four electrode types was placed in three orientations: (1) bilateral, (2) ipsilateral mediolateral, and (3) ipsilateral craniocaudal. Results Four surgical cases were utilized for data collection with the repetitive measures obtained in each subject. Bilateral electrode orientation was superior to ipsilateral craniocaudal and ipsilateral mediolateral orientations. Regardless of electrodes type, all amplitudes in the bilateral orientation were >100 μV. When placed bilaterally, the small‐foot adhesive and the long‐needle electrodes obtained the highest EMG amplitudes as a percentage of ETT amplitudes. Conclusion Cutaneous electrodes could potentially be used to monitor the VN during thyroid and parathyroid procedures. Different electrode types vary in their ability to record amplitudes and latencies. Bilateral orientation improves EMG responses in all electrode types. Additional validation of cutaneous electrodes as an alternative noninvasive method to monitor the VN is needed.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.