  • Path-Integrated Stereo X-Ra...
    Jones, EMC

    Experimental mechanics, 04/2024, Letnik: 64, Številka: 3
    Journal Article

    Background X-ray imaging addresses many challenges with visible light imaging in extreme environments, where optical diagnostics such as digital image correlation (DIC) and particle image velocimetry (PIV) suffer biases from index of refraction changes and/or cannot penetrate visibly occluded objects. However, conservation of intensity—the fundamental principle of optical image correlation algorithms—may be violated if ancillary components in the X-ray path besides the surface or fluid of interest move during the test. Objective The test series treated in this work sought to characterize the safe use of fiber-epoxy composites in aerospace and aviation industries during fire accident scenarios. Stereo X-ray DIC was employed to measure test unit deformation in an extreme thermal environment involving a visibly occluded test unit, incident surface heating to temperatures above 600 o C, and flames and soot from combusting epoxy decomposition gasses. The objective of the current work is to evaluate two solutions to resolve the violation of conservation of intensity that resulted from both the test unit and the thermal chamber deforming during the test. Methods The first solution recovered conservation of intensity by pre-processing the path-integrated X-ray images to isolate the DIC pattern of the test unit from the thermal chamber components. These images were then correlated with standard, optical DIC software. The second solution, called Path-Integrated Digital Image Correlation (PI-DIC), modified the fundamental matching criterion of DIC to account for multiple, independently-moving components contributing to the final image intensity. The PI-DIC algorithm was extended from a 2D framework to a stereo framework and implemented in a custom DIC software. Results Both solutions accurately measured the cylindrical shape of the undeformed test unit, recovering radii values of R = 76.20 ± 0.12  mm compared to the theoretical radius of R theor = 76.20  mm. During the test, the test unit bulged asymmetrically as decomposition gasses pressurized the interior and eventually burned in a localized jet. Both solutions measured the heterogeneous radius of this bulge, which reached a maximum of approximately R = 91  mm, with a discrepancy of 2–3% between the two solutions. Conclusions Two solutions that resolve the violation of conservation of intensity for path-integrated X-ray images were developed. Both were successfully employed in a stereo X-ray DIC configuration to measure deformation of an aluminum-skinned, fiber-epoxy composite test unit in a fire accident scenario.