Lemp, Michael A; Bron, Anthony J; Baudouin, Christophe; Benítez del Castillo, José M; Geffen, David; Tauber, Joe; Foulks, Gary N; Pepose, Jay S; Sullivan, Benjamin D
American journal of ophthalmology, 05/2011, Letnik: 151, Številka: 5Journal Article
Purpose To evaluate the use of tear osmolarity in the diagnosis of dry eye disease. Design A prospective, observational case series to determine the clinical usefulness of tear osmolarity and commonly used objective tests to diagnose dry eye disease. Methods A multicenter, 10-site study consisting of 314 consecutive subjects between 18 and 82 years of age. Bilateral tear osmolarity, tear film break-up time (TBUT), corneal staining, conjunctival staining, Schirmer test, and meibomian gland grading were performed. Diagnostic performance was measured against a composite index of objective measurements that classified subjects as having normal, mild or moderate, or severe dry eye. The main outcome measures were sensitivity, specificity, area under the receiver operating characteristic curve, and intereye variability. Results Of the 6 tests, tear osmolarity was found to have superior diagnostic performance. The most sensitive threshold between normal and mild or moderate subjects was found to be 308 mOsms/L, whereas the most specific was found at 315 mOsms/L. At a cutoff of 312 mOsms/L, tear hyperosmolarity exhibited 73% sensitivity and 92% specificity. By contrast, the other common tests exhibited either poor sensitivity (corneal staining, 54%; conjunctival staining, 60%; meibomian gland grading, 61%) or poor specificity (tear film break-up time, 45%; Schirmer test, 51%). Tear osmolarity also had the highest area under the receiver operating characteristic curve (0.89). Intereye differences in osmolarity were found to correlate with increasing disease severity ( r2 = 0.32). Conclusions Tear osmolarity is the best single metric both to diagnose and classify dry eye disease. Intereye variability is a characteristic of dry eye not seen in normal subjects.
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.