Andriamirado, M; Balantekin, A B; Bass, C D; Bergeron, D E; Bernard, E P; Bowden, N S; Bryan, C D; Carr, R; Classen, T; Conant, A J; Delgado, A; Diwan, M V; Dolinski, M J; Erickson, A; Foust, B T; Gaison, J K; Galindo-Uribarri, A; Gilbert, C E; Gokhale, S; Grant, C; Hans, S; Hansell, A B; Heeger, K M; Heffron, B; Jaffe, D E; Jayakumar, S; X Ji; Jones, D C; Koblanski, J; Kunkle, P; Lane, C E; Langford, T J; LaRosa, J; Littlejohn, B R; X Lu; Maricic, J; Mendenhall, M P; Meyer, A M; Milincic, R; Mueller, P E; Mumm, H P; Napolitano, J; Neilson, R; Nikkel, J A; Nour, S; Palomino, J L; Pushin, D A; Qian, X; Roca, C; Rosero, R; Searles, M; Surukuchi, P T; Sutanto, F; Tyra, M A; Venegas-Vargas, D; Weatherly, P B; Wilhelmi, J; Woolverton, A; Yeh, M; Zhang, C; Zhang, X
arXiv (Cornell University), 04/2023Paper, Journal Article
This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. The expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.
Avtor
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.