NUK - logo
E-viri
Recenzirano Odprti dostop
  • Use of PBPK Modeling To Eva...
    Hassoun, Mireille; Malmlöf, Maria; Scheibelhofer, Otto; Kumar, Abhinav; Bansal, Sukhi; Selg, Ewa; Nowenwik, Mattias; Gerde, Per; Radivojev, Snezana; Paudel, Amrit; Arora, Sumit; Forbes, Ben

    Molecular pharmaceutics, 03/2019, Letnik: 16, Številka: 3
    Journal Article

    The dissolution of inhaled drug particles in the lungs is a challenge to model using biorelevant methods in terms of (i) collecting a respirable emitted aerosol fraction and dose, (ii) presenting this to a small volume of medium that is representative of lung lining fluid, and (iii) measuring the low concentrations of drug released. We report developments in methodology for each of these steps and utilize mechanistic in silico modeling to evaluate the in vitro dissolution profiles in the context of plasma concentration-time profiles. The PreciseInhale aerosol delivery system was used to deliver Flixotide aerosol particles to Dissolv It apparatus for measurement of dissolution. Different media were used in the Dissolv It chamber to investigate their effect on dissolution profiles, these were (i) 1.5% poly(ethylene oxide) with 0.4% l-alphaphosphatidyl choline, (ii) Survanta, and (iii) a synthetic simulated lung lining fluid (SLF) based on human lung fluid composition. For fluticasone proprionate (FP) quantification, solid phase extraction was used for sample preparation with LC-MS/MS analysis to provide an assay that was fit for purpose with a limit of quantification for FP of 312 pg/mL. FP concentration-time profiles in the flow-past perfusate were similar irrespective of the medium used in the Dissolv It chamber (∼0.04-0.07%/min), but these were significantly lower than transfer of drug from air-to-perfusate in isolated perfused lungs (0.12%/min). This difference was attributed to the Dissolv It system representing slower dissolution in the central region of the lungs (which feature nonsink conditions) compared to the peripheral regions that are represented in the isolated lung preparation. Pharmacokinetic parameters ( C , T , and AUC ) were estimated from the profiles for dissolution in the different lung fluid simulants and were predicted by the simulation within 2-fold of the values reported for inhaled FP (1000 μg dose) administered via Flixotide Evohaler 250 μg strength inhaler in man. In conclusion, we report methods for performing biorelevant dissolution studies for orally inhaled products and illustrate how they can provide inputs parameters for physiologically based pharmacokinetic (PBPK) modeling of inhaled medicines.