NUK - logo
E-viri
Celotno besedilo
Recenzirano
  • FM/PWM control scheme in cl...
    Sekiya, H.; Koizumi, H.; Mori, S.; Sasase, I.; Jianming Lu; Yahagi, T.

    IEEE transactions on circuits and systems. I, Regular papers, 07/2004, Letnik: 51, Številka: 7
    Journal Article

    This paper presents a new control scheme for a Class DE inverter, that is, frequency modulation/pulsewidth modulation (FM/PWM) control. Further, the FM/PWM controlled Class DE inverter is analyzed and we clarify performance characteristics. Since the FM/PWM controlled inverter has two control parameters, namely, the switching frequency and the switch-on duty ratio, it has one more degree of freedom for the control than the inverter with the conventional control scheme. The increased degree of freedom is used to minimize the switching losses. Therefore, it is possible to control the output power with high power-conversion efficiency for wide-range control. Carrying out the circuit experiments, we confirm that the experimental results agree well with the theoretical predictions quantitatively. For example, the proposed controlled inverter can control the output voltage from 56% to 191% of the optimum one, which is designed for 1.8 W at 1.0 MHz, with maintaining over 90% power-conversion efficiency.