Pollet, Jeroen; Delport, Filip; Janssen, Kris P.F.; Jans, Karolien; Maes, Guido; Pfeiffer, Helge; Wevers, Martine; Lammertyn, Jeroen
Biosensors & bioelectronics, 12/2009, Letnik: 25, Številka: 4Journal Article
In this paper we present a fiber optic surface plasmon resonance (SPR) sensor as a reusable, cost-effective and label free biosensor for measuring DNA hybridization and DNA–protein interactions. This is the first paper that combines the concept of a fiber-based SPR system with DNA aptamer bioreceptors. The fibers were sputtered with a 50nm gold layer which was then covered with a protein repulsive self-assembled monolayer of mixed polyethylene glycol (PEG). Streptavidin was attached to the PEG's carboxyl groups to serve as a versatile binding element for biotinylated ssDNA. The ssDNA coated SPR fibers were first evaluated as a nucleic acid biosensor through a DNA–DNA hybridization assay for a random 37-mer ssDNA. This single stranded DNA showed a 15 nucleotides overlap with the receptor ssDNA on the SPR fiber. A linear calibration curve was observed in 0.5–5μM range. A negative control test did not reveal any significant non-specific binding, and the biosensor was easily regenerated. In a second assay the fiber optic SPR biosensor was functionalized with ssDNA aptamers against human immunoglobulin E. Limits of detection (2nM) and quantification (6nM) in the low nanomolar range were observed. The presented biosensor was not only useful for DNA and protein quantification purposes, but also to reveal the binding kinetics occurring at the sensor surface. The dissociation constant between aptamer and hIgE was equal to 30.9±2.9nM. The observed kinetics fully comply with most data from the literature and were also confirmed by own control measurements.
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|
Vir: Osebne bibliografije
in: SICRIS
To gradivo vam je dostopno v celotnem besedilu. Če kljub temu želite naročiti gradivo, kliknite gumb Nadaljuj.