ALL libraries (COBIB.SI union bibliographic/catalogue database)
-
Cable aging monitoring with differential scanning calorimetry (DSC) in nuclear power plantsPirc, Marko, 1972- ...As a requirement for plant life extension for more than 40 years, additional Cable Aging Management Program (CAMP) has to be implemented in Nuclear Power Plant Krško. Samples of cables are selected ... based on nuclear safety and electrical equipment criticality for inspection and testing, to check functionality and prevent unexpected failure during normal operation. Different onsite testing equipment and methods are implemented to find harsh environment due to temperature, radiation, humidity and chemical effects that could affect insulation lifetime. Infrared thermography is used for determining and evaluating temperature hot spots. The article presents a development of laboratory testing of cable insulation using Differential Scanning Calorimetry (DSC). Thirty-six samples of different nuclear qualified cables made of most frequently used materials, ethylene propylene rubber (EPR) and cross linked polyethylene (XLPE) - all with chlorosulfonated polyethylene (CSPE) jacket, were tested. Samples were 35 years old and additionally temperature aged in several steps with an intention to get acceptance criteria. Similar tests were conducted in two testing laboratories. The results showed an evident decrease in oxidation stability of the inner EPR insulation; the onset temperature of oxidation processes has been shifted from 238 °C (unaged samples) to 175 °C (most aged samples). A decrease in oxidation stability was also observed for XPLE insulation; the onset oxidation temperature decreased from 266 °C for unaged samples to 213 °C (most aged samples). For the jacket material CSPE used as the insulation protection nearly no changes were observed.Source: Transactions of FAMENA. - ISSN 1333-1124 (Vol. 42, spec. issue 1, 2018, str. 87-98)Type of material - article, component partPublish date - 2018Language - englishCOBISS.SI-ID - 1024306268
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Pirc, Marko, 1972- | 51173 |
Avsec, Jurij | 10827 |
Čelan Korošin, Nataša | 21628 |
Lavrenčič Štangar, Urška | 11873 |
Cerc Korošec, Romana | 16256 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
Pickup location | Material status | Reservation |
---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: