ALL libraries (COBIB.SI union bibliographic/catalogue database)
-
Effects of the fire decay phase on the bending capacity of a fire-exposed reinforced-concrete slab [Elektronski vir]Jovanović, Balša ...The decay phase can have an important role in the behaviour and failure of the structure during and after a fire, and therefore, it should be properly defined. The most commonly used method to define ... natural fire exposure, the Eurocode parametric fire curve (EN 1991-1-2:2002), adopts a simplified linear approximation of the fire decay phase with a constant cooling rate defined in function of compartment characteristics. In this study an analysis of the influence of the decay phase cooling rate assumption on structural behaviour is made, considering the case of a simply supported reinforced-concrete slab exposed to fire from the bottom side. It is demonstrated that the cooling rate of the decay phase can have a significant effect on the reduction of the slab’s bending capacity. It is also shown that the magnitude of this influence is affected by both the temperatures during the heating phase and the size of the concrete cover. The case study demonstrates that the difference between the cooling rates from the Eurocode parametric fire curve and available experimental test results are significant, and that this can have a significant effect on the assessment of the slab’s structural performance.Source: Proceedings of the international conference in Ljubljana, 10-11 June, 2021 [Elektronski vir] (Str. 1-6)Type of material - conference contribution ; adult, seriousPublish date - 2021Language - englishCOBISS.SI-ID - 107725059
Author
Jovanović, Balša |
Lucherini, Andrea |
Van Coile, Ruben |
Merci, Bart |
Caspeele, Robby |
Reynders, Edwin |
Lombaert, Geert
Topics
požar |
požarno inženirstvo |
AB plošče |
konstrukcije |
fire decay phase |
parametric fire |
natural fire |
compartment fire dynamics |
structural fire engineering
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Jovanović, Balša | ![]() |
Lucherini, Andrea | 56534 |
Van Coile, Ruben | ![]() |
Merci, Bart | ![]() |
Caspeele, Robby | ![]() |
Reynders, Edwin | ![]() |
Lombaert, Geert | ![]() |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
Pickup location | Material status | Reservation |
---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: