-
Effect of vibration and noise measuring points distribution on the sensitivity of pump cavitation diagnosisZhou, Runze ...Cavitation is an essential factor in the deterioration of the hydraulic performance of centrifugal pumps. The study of cavitation fault diagnosis can help avoid or reduce the damage it causes. The ... vibration and noise analysis method can predict the incipient cavitation more accurately. In order to improve the accuracy of cavitation fault diagnosis, this paper studies the distribution of vibration and noise measuring points for centrifugal pump cavitation diagnosis. The research object is a centrifugal pump with an inducer and splitter blades. Vibration acceleration sensors and hydrophones were used to collect structural vibration and liquid-borne noise signals at different positions of the pump unit. Root-mean-square (RMS) and fast Fourier transform (FFT) methods were used to construct spectrums of vibration and noise signals with different NPSH and compare the sensitivity of different measuring points to the inception and development of cavitation. In addition, the SST k-ω turbulence model and Zwart cavitation model were used to study the cavitation volume distribution in the pump under different cavitation stages. By setting monitoring points at the impeller outlet, the frequency domain signal distribution of pressure pulsation was studied. The results show that the vibration acceleration measuring points at the pump inlet flange and pump axial position, and liquid-borne noise measuring point at the inlet position, are more sensitive to the diagnosis of cavitation fault. Motor current is also the basis for judging the inception of cavitation. Moreover, as the cavitation intensifies, the dominant frequency signal of the pressure pulsation in the pump is partially shifted.Source: Strojniški vestnik = Journal of mechanical engineering. - ISSN 0039-2480 (Vol. 68, no. 5, 2022, str. 325-338)Type of material - article, component part ; adult, seriousPublish date - 2022Language - englishCOBISS.SI-ID - 111026435
Author
Zhou, Runze |
Chen, Hui, strojnik |
Dong, Liang, strojnik |
Liu, Houlin |
Chen, Zeyu |
Zhang, Yuhang |
Cheng, Zhiming
Topics
cavitation |
centrifugal pumps |
vibration |
noise |
measuring points |
spectral analysis |
kavitacija |
centrifugalne črpalke |
vibracije |
hrup |
merilne točke |
spektralne analize
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Zhou, Runze | |
Chen, Hui, strojnik | |
Dong, Liang, strojnik | |
Liu, Houlin | |
Chen, Zeyu | |
Zhang, Yuhang | |
Cheng, Zhiming |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.