Experimental investigation of air-based active-passive system for cooling application in buildings [Elektronski vir]Zavrl, Eva, 1991- ...Due to the consequences of global warming, cooling of lightweight buildings is one of the main future challenges. The study presents an active-passive system (APS) with phase change material (PCM) ... plates integrated into the internal wall and ceiling substructure which during the day cools the indoor space passively. During the night, the air gap is ventilated actively to improve the PCM solidification process. The APS was experimentally tested in two identical test cells, PCM modified (cell-A) and reference cell (cell-B). Two different types of scenarios were investigated. First type tested the cooling effect of the PCM during the daytime cycle, determined by the temperature difference between the cell-B and cell-A. The same amount of heat was simultaneously added to both cells which was navigated by the setpoint air temperature in the cell-B (26°C, 30°C, 30°C with background ventilation, 35°C, TRY Ljubljana, TRY Rome and heatwave Ljubljana). Second type tested the PCM solidification time during the nighttime cycle (inlet air temperature (Tai) of 15°C, 16°C, and 17°C). The results showed that PCM plates provided the largest cooling effect at in 35°C-scenario. The complete solidification of PCM was achieved at Tai of 16°C. The system is adequate for Mediterranean summer conditions.Source: Sustainable cities and society [Elektronski vir]. - ISSN 2210-6715 (Vol. 85, Oct. 2022, str. 1-13)Type of material - e-article ; adult, seriousPublish date - 2022Language - englishCOBISS.SI-ID - 117204483
Author
Zavrl, Eva, 1991- |
El Mankibi, Mohamed |
Dovjak, Mateja |
Stritih, Uroš
Topics
nočno prezračevanje |
fazno spremenljivi materiali |
hlajenje |
reševanje pregrevanja |
prezračevanje |
zalogovniki toplote |
prezračevana zračna plast |
PCM integrirani v stavbne elemente |
nightime ventilation |
phase change materials |
cooling |
overheating reductions |
ventilation |
thermal energy storage |
ventilated air gap |
PCM integrated building elements
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Zavrl, Eva, 1991- | 54079 |
El Mankibi, Mohamed | ![]() |
Dovjak, Mateja | 29265 |
Stritih, Uroš | 15163 |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.