ALL libraries (COBIB.SI union bibliographic/catalogue database)
-
Detection of physiological control inputs preload and afterload from intrinsic pump parameters in total artificial heartKirn, Borut ...Background In the total artificial heart (TAH), the inputs to the physiological control unit, preload, and afterload, are detected from intrinsic pump parameters (e.g., motor current). Within this ... study their detection techniques are developed, and their reliability in pre- and afterload prediction are mapped for a broad range of cardiovascular system states. Methods We used ReinHeart TAH which is a fully implantable TAH with plunger coil drive that is alternately emptying the left and right chamber. From the coil currents we first derived a force generated by the piston with respect to its position and then analyzed its pattern to detect 1) preload - chamber filling, found as piston position at begin ejection and 2) afterload - mean outflow pressures, determined as linearly calibrated average piston force during ejection. TAH is then integrated into a mock loop circulation (MLC) which is set to 135 different steady operating points varying in chamber filling (0–100%, five steps), mean outflow pressures (system circulation: 60-90-120 mmHg, pulmonary circulation: 15-30-45 mmHg), and heart cycle duration (171–600 ms in seven non-equidistant steps). The detected preload and afterload are compared to MLC set values, and the errors are mapped. Results Respectively for left and right chamber the preload was detectable in 134 and 118 operating points and the mean error was ±3% and ±2%. The afterload was detectable in 135 and 87 operating points and mean error was 37% and 30% respectively for left and right circulation. The operational points that are further away from homeostatic equilibrium values generally yielded larger errors. Largest errors were observed for right circulation at long cycle duration, low afterload, and at low filling. Conclusions The study yields reliable preload estimation in a broad range of physiological states, particularly for left circulation. Detection of afterload needs further improvements. The study revealed a need for piston movement optimization within the ReinHeart TAH during the early phase of systole.Source: Artificial organs. - ISSN 0160-564X (Vol. 47, iss. 5, May 2023, str. 817-827)Type of material - article, component part ; adult, seriousPublish date - 2023Language - englishCOBISS.SI-ID - 133370371
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Kirn, Borut | 16344 |
Diedrich, Mario | |
Schmitz-Rode, Thomas | |
Steinseifer, Ulrich | |
Jansen, Sebastian V. |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
Pickup location | Material status | Reservation |
---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: