ALL libraries (COBIB.SI union bibliographic/catalogue database)
PDF
  • Thermo-economic and primary-energy-factor assessment based on the field test of an air-to-water heat pump
    Poredoš, Primož, strojnik, 1986- ...
    This paper presents the results of a thermo-economic and primary-energy-factor assessment based on the field-test results for a residential air-to-water heat pump (AWHP). The AWHP experimental setup ... consisted of a supervisory control and data-acquisition system, which was connected to a heat meter, an electricity meter, humidity and temperature sensors, a HP control system and a computer. Based on the experimental data, the 4-year-average seasonal performance factor was determined. This information was then applied in a thermo-economic and primary-energy-factor (PEF) analysis. The results served for a comparison of the AWHP with eight different heating systems (HSs). The results reveal that the considered AWHP represents the most thermo-economically efficient system in terms of the average final costs for heat production. The results of the PEF analysis reveal that the HS with the AWHP under investigation can be characterized as the most efficient system.
    Type of material - article, component part ; adult, serious
    Publish date - 2017
    Language - english
    COBISS.SI-ID - 15291163