ALL libraries (COBIB.SI union bibliographic/catalogue database)
-
Cardiac electromechanical activity in healthy cats and cats with cardiomyopathies [Elektronski vir]Brložnik, Maja ...Optimal heart function depends on perfect synchronization between electrical and mechanical activity. In this pilot study, we aimed to investigate the electromechanical activity of the heart in ... healthy cats and cats with cardiomyopathy with phonocardiography (PCG) synchronized to an electrocardiography (ECG) pilot device. We included 29 cats (12 healthy cats and 17 cats diagnosed with cardiomyopathy) and performed a clinical examination, PCG synchronized with ECG and echocardiography. We measured the following durations with the pilot PCG device synchronized with ECG: QRS (ventricular depolarization), QT interval (electrical systole), QS1 interval (electromechanical activation time (EMAT)), S1S2 (mechanical systole), QS2 interval (electrical and mechanical systole) and electromechanical window (end of T wave to the beginning of S2). The measured parameters did not differ between healthy cats and cats with cardiomyopathy; however, in cats with cardiomyopathy, EMAT/RR, QS2/RR and S1S2/RR were significantly longer than in healthy cats. This suggests that the hypertrophied myocardium takes longer to generate sufficient pressure to close the mitral valve and that electrical systole, i.e., depolarization and repolarization, and mechanical systoles are longer in cats with cardiomyopathy. The PCG synchronized with the ECG pilot device proved to be a valuable tool for evaluating the electromechanical activity of the feline heart.Source: Sensors [Elektronski vir]. - ISSN 1424-8220 (Vol. 29, issue 19, [art. no.] 8336, 2023, str. 1-13)Type of material - e-article ; adult, seriousPublish date - 2023Language - englishCOBISS.SI-ID - 167620099
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Brložnik, Maja | 57701 |
Lunka, Ema | |
Avbelj, Viktor, 1956- | 03302 |
Nemec Svete, Alenka | 16308 |
Domanjko-Petrič, Aleksandra | 10395 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
Pickup location | Material status | Reservation |
---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: