Verification, implementation and harmonization of automated chemiluminescent immunoassays for MPO- and PR3-ANCA detection [Elektronski vir]Ogrič, Manca ...Objectives: Antineutrophil cytoplasmic antibody (ANCA) testing assists clinicians diagnose ANCA-associated vasculitis (AAV). We aimed to verify and harmonize chemiluminescent immunoassays for the ... detection of myeloperoxidase (MPO)- and proteinase 3 (PR3)-ANCA. Methods: An in-house ELISA, a capture ELISA, and a chemiluminescent assay QUANTA Flash on a BIO-FLASH analyzer were used to detect MPO- and PR3-ANCA in sera from 39 patients with AAV, 55 patients with various non-AAV, and 66 patients with connective tissue diseases. The results of the assays were evaluated, and their clinical performance was assessed. The precision and linearity of the QUANTA Flash assays were determined, and likelihood ratios (LRs) for AAV at diagnosis were calculated. Results: The precision and linearity of the QUANTA Flash assays were confirmed. Overall agreement between 97.5 and 98.8 % and Cohen's kappa coefficients between 0.861 and 0.947 were observed for the results of the QUANTA Flash assays and ELISAs. The diagnostic sensitivity, specificity, and ROC analysis of the assays for AAV were statistically similar (in-house ELISA 89.7 %, 95.0 %, and 0.937; capture ELISA 92.3 %, 98.3 %, and 0.939; and QUANTA Flash 89.7 %, 95.9 %, and 0.972). For the QUANTA Flash assay results, the interval-specific LRs for AAV at diagnosis were: 0-8 CU had LR 0.08, 8-29 CU had LR 1.03, 29-121 CU had LR 7.76, 121-191 CU had LR 12.4, and >191 CU had LR ∞. Conclusions: The QUANTA Flash MPO and PR3 assays provide precise and consistent results and have comparable clinical utility for AAV. The calculated LRs were consistent with published LRs, confirming the utility of LRs for harmonization of ANCA results.Source: Clinical chemistry and laboratory medicine. - ISSN 1437-4331 (Vol. 62 [article no.] 0764, iss. 4, 2023, str. 682-689)Type of material - e-articlePublish date - 2023Language - englishCOBISS.SI-ID - 169691907
Author
Ogrič, Manca |
Švec, Tinka |
Mrak Poljšak, Katjuša |
Žigon, Polona, 1978- |
Hočevar, Alojzija |
Čučnik, Saša
Topics
antineutrophil cytoplasmic antibodies (ANCA) |
proteinase 3 (PR3) |
myeloperoxidase (MPO) |
ANCA-associated vasculitis (AAV) |
chemiluminescent immunoassay |
likelihood ratios (LRs) |
antinevtrofilna citoplazemska protitelesa (ANCA) |
proteinaza 3 (PR3) |
mieloperoksidaza (MPO) |
vaskulitis, povezan z ANCA (AAV) |
kemiluminiscentni imunski test |
razmerja verjetnosti (LR)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Ogrič, Manca | 38271 |
Švec, Tinka | 21943 |
Mrak Poljšak, Katjuša | 34804 |
Žigon, Polona, 1978- | 24206 |
Hočevar, Alojzija | 22344 |
Čučnik, Saša | 16362 |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.