  • Validation of calculated self-shielding factors for Rh foils
    Jaćimović, Radojko ...
    Rhodium foils of about 5 mm diameter were obtained from IRMM. One foil had thickness of 0.006 mm and three were 0.112 mm thick. They were irradiated in the pneumatic transfer system and in the ... carousel facility of the TRIGA reactor at the Jozef Stefan Institute. The foils were irradiated bare and enclosed in small cadmium boxes (about 2 g weight) of 1 mm thickness to minimise the perturbation of the local neutron flux. They were co-irradiated with 5 mm diameter and 0.2 mm thick Al-Au (0.1%) alloy monitor foils. The resonance self-shielding corrections for the 0.006 and 0.112 mm thick samples were calculated by the Monte Carlo simulation and amount to about 10% and 60%,respectively. The consistency of measurements confirmed the validity of self-shielding factors. Trial estimates of Q0 and k0 factors for the 555.8 keVgamma line of 104Rh were made and amount to 6.65 0.18 and (6.61 0.12)*10-2,respectively.
    Source: Proceedings (Vol. 622, 2010, str. 399-402)
    Type of material - conference contribution
    Publish date - 2010
    Language - english
    COBISS.SI-ID - 23905831