ALL libraries (COBIB.SI union bibliographic/catalogue database)
-
Accuracy of root canal length determination with the impedance ratio methodJan, Janja ; Križaj, Dejan, 1962-Aim To provide insight into the principles of operation of electronic apex locators, determine optimal measuring parameters of the impedance ratio method, and to evaluate its accuracy. Methodology ... Electrical impedance was measured ex vivo on 14 extracted human teeth using a QuadTech 1920 precision impedance analyzer. A file electrode was inserted into the root canal; the second electrode was placed in the saline solution surrounding the tooth. Measurements were performed in a frequency range from 20 Hz to 1 MHz, and repeated with different distances of the file tip from the major apical foramen. The measured impedances were analysed as a function of distance of the file tip to the major apical foramen. Parameters (e.g. measurement frequencies, impedance ratio value) that would result in optimal working length determination were evaluated. Results The optimal determination of the major apical foramen position was obtained at frequencies of 5 kHz and 0.5 kHz, 10 kHz and 0.5 kHz, and 5 kHz and 1 kHz, for the impedance ratios 0.73 (95% CI: -0.33 to 1.74 mm), 0.66 (95% CI: -0.34 to 1.81 mm) and 0.79 (95% CI: -0.33 to 1.58 mm) respectively. The limit of +/-0.5 mm was attained in 86% of all measurements. Standard deviations decreased as the average measured distance approached and extended beyond the major apical foramen. Conclusions With the obtained optimal measuring parameters, the impedance ratio method determined position of the major foramen within +/-0.5 mm. Accuracy varied depending on the set of frequencies used for evaluation as well as on the selected impedance ratio.Source: International endodontic journal. - ISSN 0143-2885 (Letn. 42, 2009, str. 819-826)Type of material - article, component partPublish date - 2009Language - englishCOBISS.SI-ID - 25834969
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Jan, Janja | 15470 |
Križaj, Dejan, 1962- | 10269 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
Pickup location | Material status | Reservation |
---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: