Can be sphincter electromyography reference values shared between laboratories?Podnar, Simon ; Gregory, Thomas W.Aims: Sphincter electromyography (EMG) is an important method in diagnosis of neuropathic sacral lesions. Quantitative EMG analysis increases utility of thetest, but requires valid reference values. ... Although commonly employed, validity of sharing reference data between electrodiagnostic laboratories has not been confirmed. In this study, this approach was assessed by comparing thereproducibility of data sets obtained by the same and different laboratories. Methods: Confidence intervals and sensitivity of motor unit potential (MUP) parameters in the external anal sphincter (EAS) muscles were calculated using data obtained from three different control groups of women (number of women: 41, 48, and 66), examined by the same (the first two groups) and another investigator (the third group). Sensitivities to diagnose neuropathic changes in a known patient group were compared. Results: When compared to the first reference group, the MUP parameter means of 2/7 (same investigator) versus 3/7 (different investigator) were significantly different. Similarly, 3/14 versus 4/14 MUP parameter outliers were different. Finally, 6/14 versus 7/14 sensitivities (using a combination of MUP parameter means and outliers) were different. Conclusion: This study demonstrated somewhat larger differences between confidence intervals obtained by different investigators, as compared to those obtained by a single investigator. However, most of these differences can be explained by differences in recruited groups of women, and slight inconsistencies in applied techniques. Presented data suggest that confidence intervals from other laboratories can be used, but only if exact protocols from original normative studies are strictly followed.Source: Neurourology and urodynamics. - ISSN 0733-2467 (Letn. 29, št. 8, 2010, str. 1387-1392)Type of material - article, component partPublish date - 2010Language - englishCOBISS.SI-ID - 27577561
Author
Podnar, Simon |
Gregory, Thomas W.
Topics
Electromyography |
Anus |
Lumbosacral Plexus |
Nerve Compression Syndromes |
Diagnosis |
Motor Neurons |
Reproducibility Of Results |
Laboratories, Hospital |
Sensitivity And Specificity |
Elektromiografija |
Anus |
Lumbosakralni pletež |
Motorični nevroni |
Živec, utesnitveni sindromi |
Ponovljivost rezultatov |
Občutljivost in specifičnost |
Laboratoriji bolnišnični

Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Impact factor
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Podnar, Simon | 14502 |
Gregory, Thomas W. | ![]() |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.