  • Development of MPPC-based detectors for high count rate DT campaigns at JET
    Boltruczyk, G. ...
    The products of fusion reactions at JET are measured using different diagnostic techniques. One of the methods is based on measurements of gamma-rays, originating from reactions between fast ions and ... plasma impurities. During the forthcoming deuterium-tritium (DT) campaign a particular attention will be paid to 4.44 MeV gamma-rays emitted in the Be-9(alpha,n gamma)C-12 reaction. Gamma-ray detectors foreseen for measurements in DT campaigns have to be able to register spectra at high count rates, up to approximately 500 kHz. For the Gamma-ray Camera at JET a new setup will be based on scintillators with a short decay time, e.g., CeBr3, and a multi-pixel photon counter (MPPC). We present two methods of output signal shortening in modules based on MPPC. A short detector output signal is necessary in order to minimize the number of pile up events at high count rates. One method uses a passive RC circuit with a pole zero cancellation, whereas an active transimpedance amplifier is used in the other one. Due to the strong dependence of MPPC properties on temperature variation, a special device MTCD@NCBJ was designed and produced to stabilize the gain in MPPC-based scintillation detectors. We show that this device guarantees stable working conditions.
    Source: 29th Symposium on fusion technology (Vol. 123, 2017, str. 940-944)
    Type of material - conference contribution
    Publish date - 2017
    Language - english
    COBISS.SI-ID - 32626215