Experimental determination of field output factors and detector specific output correction factors in small fields of megavoltage radiotherapy beams [Elektronski vir]Casar, BožidarThe goal of this work was to determine field output factors, ▫$\Omega^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫, using EBT3 radiochromic films and W1 plastic scintillator as reference detectors on two ... different linear accelerators. Secondly, we aimed to provide a large and consistent set of data for detector specific output correction factors, ▫$k^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫, for small static fields for seven solid state detectors and seven small ionization chambers. In the case of ionization chambers, ▫$k^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫ were determined in two orientations - parallel and perpendicular, to test the hypothesis, that ▫$k^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫ are lower and therefore advantageous for parallel orientation. ▫$\Omega^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫ were determined for 6 and 10 MV photon beams with and without flattening filter and for nine fields ranging from 0.5 x 0.5 ▫$cm^2$▫ to 10 x 10 ▫$cm^2$▫. Signal readings obtained with EBT3 radiochromic films and W1 plastic scintillator were fitted by an analytical function. ▫$k^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫ were determined empirically for 14 clinically used small detectors, under the same experimental conditions. It has been found that, for a given linear accelerator, ▫$\Omega^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫ need to be determined for every combination of photon beam energy, filtration, and field size as the differences between them can be statistically significant (p < 0.05). Further, it has been demonstrated, that the parallel orientation of ionization chamber is advantageous over the perpendicular, which is an important contribution to the present international dosimetry protocol for small fields IAEA TRS-483. Use of two reference detectors for the determination of field output factors for small static fields in MV photon beams is a novel approach and has been justified in our thesis. Large set of ▫$k^{f_{clin},f_{ref}}_{Q_{clin},Q_{ref}}$▫ data for seven solid-state detectors and seven ionization chambers in four MV beams determined on two linear accelerators by a single group of researchers can be considered a valuable supplement to the literature and the IAEA TRS-483 dataset. Recommendation on the orientation of ionization chambers is the last significant outcome of our work.Type of material - dissertation ; adult, seriousPublication and manufacture - [Zagreb : B. Casar], 2019Language - englishCOBISS.SI-ID - 3265659
Author
Casar, Božidar
Other authors
Jurković, Slaven |
Jeraj, Robert
Topics
radioterapija |
dozimetrija |
W1 scintilator |
EBT3 filmi |
diode |
ionizacijske komore |
disertacije |
radiotherapy |
dosimetry |
W1 scintillator |
EBT3 films |
diodes |
ionization chambres |
disertations
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Casar, Božidar | 15973 |
Jurković, Slaven | |
Jeraj, Robert | 15737 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
Pickup location | Material status | Reservation |
---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: