Assessment of overhead transmission line lightning performance with improved EGM [Elektronski vir]Bečan, Miha, 1982- ...In the past the overhead transmission lines (OTL) in Slovenia were designed and built disregarding the reliably assessed expected lightning performance. Therefore, it was impossible to improve the ... lightning performance in the design phase. The importance of OTL performance has increased since the transmission capacity became scarce. For a statistical evaluation of the existing and new OTLs lightning performance the SigmaSLP computer programme with lightning data obtained by SCALAR, the Slovenian Centre for the Automatic Lightning Localisation, was introduced. The results obtained by the electro geometric modelling (EGM) of a typical Slovenian 2 x 110 kV OTL with only one ground wire showed high dependence on the nearby objects heights. The analysis showed that without taking the nearby object into account the direct lightning stroke protection is not efficient. The major parts of lightning strokes directly touch the phase wire. Direct lightning strokes into the phase wire almost always cause a flashover, although such lightning strikes have lower crest currents. Due to computer software EGM limitations the simulations of real surface configurations were done. Real right of the way surface level, vegetation height and overhead transmission line geometry were obtained with aerial laser survey. Slovenian TSO engaged a highly specialised company Flycom in order provide for a suitable OTL aerial laser survey. Based on these data the simulation of lightning impact using Monte Carlo method was implemented.Source: Power quality and lightning [Elektronski vir] : programme (Str. 1-6)Type of material - conference contribution ; adult, seriousPublish date - 2012Language - englishCOBISS.SI-ID - 36699653
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Bečan, Miha, 1982- | 29793 |
Babuder, Maks | 02907 |
Vižintin, Stane | 05516 |
Podkoritnik, Simon | 34863 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
Pickup location | Material status | Reservation |
---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: