-
Seismic risk assessment of liquid overtopping in a steel storage tank equipped with a single deck floating roofCaprinozzi, Stefano ; Paolacci, Fabrizio ; Dolšek, MatjažMajor earthquakes have demonstrated that Natech events can be triggered by liquid overtopping in liquid storage tanks equipped with floating roofs. Thus, research on the dynamic behaviour of steel ... storage tanks with floating roofs is still required. In this paper, the seismic risk against liquid overtopping in a real steel storage tank with a floating roof was analysed using a simplified model that was validated by a refined finite element model based on the arbitrary Lagrangian-Eulerian approach. The simplified model utilizes the Lagrangian of a floating roof-fluid system and is capable of providing a response history of the floating roof. It was demonstrated that it could predict the maximum vertical displacement very accurately, while some differences were observed in the response history of vertical displacement. The computational time for a single response history analysis based on the simplified model amounted to a few minutes, which is significantly less demanding compared to hours required for response history analysis in the case of the refined FE model. The simplified model is thus appro-priate for the seismic fragility analysis considering the overtopping limit state. It is shown that the fragility curves are significantly affected by the liquid filling level. The risk for liquid overtopping is quite high in the case of a full tank. However, by considering the variation of filling level during the year, the overtopping risk was observed reduced by approximately 30%. Alternatively, the approximate fragility analysis for the liquid over-topping can be performed by utilizing the Eurocode formula for the vertical displacement of liquid. This approach is straightforward, but the formula does not account for the higher mode effects, which may result in overestimated seismic intensity causing overtopping, as discussed in the paperSource: Journal of loss prevention in the process industries. - ISSN 0950-4230 (Letn. 67/104269, sept. 2020, str. 1-15)Type of material - article, component partPublish date - 2020Language - englishCOBISS.SI-ID - 37389827
Author
Caprinozzi, Stefano |
Paolacci, Fabrizio |
Dolšek, Matjaž
Topics
plavajoča streha |
jekleni rezervoarji |
poenostavljeni modeli |
podrobni modeli |
analiza potresnega tveganja |
zmanjšanje tveganja |
Evrokod 8 |
gradbeništvo |
konstrukcije |
floating roof |
steel storage tanks |
simplified model |
refined model |
petrochemical plants |
seismic fragility analysis |
seismic risk assessment |
risk mitigation |
Eurocode 8 |
civil engineering |
construction
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Caprinozzi, Stefano | |
Paolacci, Fabrizio | |
Dolšek, Matjaž | 18793 |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.