E-resources
-
Pérez-Vives, Cari; Domínguez-Vicent, Alberto; Ferrer-Blasco, Teresa; Madrid-Costa, David; Montés-Micó, Robert
Indian journal of ophthalmology, 04/2014, Volume: 62, Issue: 4Journal Article
To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Prospective study. The wavefront aberrations of two myopic (-3 and -6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro. To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were calculated from the wavefront aberrations at 3- and 4.5-mm pupil. A Student's t-test for unpaired data was used for comparison between myopic and hyperopic ICLs. Myopic ICLs showed negative spherical aberration, in contrast hyperopic ICLs showed positive spherical aberration, which increases when the ICL power increases, due to the innate optical properties of the lens. All ICLs evaluated had negligible amounts of other aberrations. We did not find statistical significant differences in any Zernike coefficient RMS values analyzed between myopic and hyperopic ICLs at 3- and 4.5-mm pupil (P > 0.05). Myopic and hyperopic ICLs provide good and comparable optical quality for low to moderate refractive error. The ICLs evaluated showed values of wavefront aberrations clinically negligible to affect the visual quality after implantation.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.