-
Center valve preference and outcomes of transcatheter aortic valve replacement : insights from the AMTRAC registryWitberg, Guy ...Background: Data on outcomes of transcatheter aortic valve replacement (TAVR) using balloon-expandable valves (BEVs) or self-expandable valves (SEVs) as well as the impact of center valve preference ... on these outcomes are limited. Objectives: The aim of this study was to compare outcomes of TAVR procedures using third-generation BEVs and SEVs stratified by center valve preference. Methods: In a multicenter registry (n = 17), 13 centers exhibited valve preference (66.6%-90% of volume) and were included. Outcomes were compared between BEVs and SEVs stratified by center valve preference. Results: In total, 7,528 TAVR procedures (3,854 with SEVs and 3,674 with BEVs) were included. The mean age was 81 years, and the mean Society of Thoracic Surgeons score was 5.2. Baseline characteristics were similar between BEVs and SEVs. Need for pacemaker implantation was higher with SEVs at BEV- and SEV-dominant centers (17.8% vs 9.3% [P < 0.001] and 12.7% vs 10.0% [P = 0.036], respectively; HR: 1.51; P for interaction = 0.021), risk for cerebrovascular accident was higher with SEVs at BEV-dominant but not SEV-dominant centers (3.6% vs 1.1% [P < 0.001] and 2.2% vs 1.4% [P = 0.162]; HR: 2.08; P for interaction < 0.01). Aortic regurgitation greater than mild was more frequent with SEVs at BEV-dominant centers and similar with BEVs regardless of center dominance (5.2% vs 2.8% [P < 0.001] and 3.4% vs 3.7% [P = 0.504], respectively). Two-year mortality was higher with SEVs at BEV-dominant centers but not at SEV-dominant centers (21.9% vs 16.9% [P = 0.021] and 16.8% vs 16.5% [P = 0.642], respectively; HR: 1.20; P for interaction = 0.032). Conclusions: Periprocedural outcomes, aortic regurgitation greater than mild, and 2-year mortality are worse when TAVR is performed using SEVs at BEV-dominant centers. Outcomes are similar regardless of valve type at SEV-dominant centers. The present results stress the need to account for this factor when comparing BEV and SEV outcomes. (The Aortic+Mitral Transcatheter [AMTRAC] Valve Registry; NCT04031274).Vir: JACC: cardiovascular interventions. - ISSN 1936-8798 (Vol. 15, iss. 12, 2022, str. 1266-1274)Vrsta gradiva - članek, sestavni delLeto - 2022Jezik - angleškiCOBISS.SI-ID - 117580035
Avtor
Witberg, Guy |
Landes, Uri |
Talmor-Barkan, Yeela |
Richter, Ilan |
Barbanti, Marco |
Valvo, Roberto |
De Backer, Ole |
Ooms, Joris F. |
Islas, Fabian |
Steblovnik, Klemen |
Bunc, Matjaž
Teme
aortic stenosis |
balloon-expandable valve |
self-expandable valve |
aortna stenoza |
samorazširljiva zaklopka |
balonsko raztegljiva zaklopka
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Witberg, Guy | |
Landes, Uri | |
Talmor-Barkan, Yeela | |
Richter, Ilan | |
Barbanti, Marco | |
Valvo, Roberto | |
De Backer, Ole | |
Ooms, Joris F. | |
Islas, Fabian | |
Steblovnik, Klemen | 50155 |
Bunc, Matjaž | 15667 |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Mesto prevzema | Status gradiva | Rezervacija |
---|
Prosimo, počakajte trenutek.