VSE knjižnice (vzajemna bibliografsko-kataložna baza podatkov COBIB.SI)
-
Elucidation of formulation and delivery device-related effects on in vitro performance of nasal spray with implication to rational product specification identificationGrmaš, Jernej ...The aim of this work is to use an experimental design approach to identify and study influential formulation and delivery device properties, which can be controlled by final product manufacturer, to ... establish design space, within which desired in vitro performance can be reached. Combining three factors, viscosity of suspension, nozzle orifice diameter (OD), and shot weight (SW), at three levels resulted in D-optimal experimental design with 20 runs. Responses within this study were droplet size distribution (DSD) and spray pattern (SP) in vitro tests. In addition, the amount of mechanical work needed for actuation was integrated from force profiles and used as a response. Results were fit to quadratic model by regression, which allowed also for determination of second-order and interaction effects between factors. Models were further optimized by keeping significant terms only. Optimized models were used to create response surfaces and design space with confidence levels. Viscosity has a dominant effect on DSD and modest effect on SP, with lower viscosities related to generation of smaller DSD and larger SP. Orifice diameter was found to have the highest impact on SP, with larger diameter resulting in larger SP. This effect was additionally confirmed by results of Plume Geometry in vitro test. Shot weight factor exerts significant influence on all tested metrics. Work, however, did not vary greatly with suspension viscosity or orifice diameter. Shot weight is the most dominant factor for work and important for DSD having a positive effect on both responses. In the case of SP, its relationship with shot weight is described by second-order polynomial fit. Inspection of raw data revealed that density of droplets within SP area is different for different shot weights. Presented study elucidated an inherent relationship between factors and responses and established mathematical models (response surfaces) for predictive purposes to target specific in vitro performance of nasal sprays by appropriate specification of factors, taking into account control space with included risk and uncertainty analysis.Vir: Journal of aerosol medicine and pulmonary drug delivery. - ISSN 1941-2711 (Vol. 30, no. 4, 2017, str. 230-246)Vrsta gradiva - članek, sestavni delLeto - 2017Jezik - angleškiCOBISS.SI-ID - 1316702
Avtor
Grmaš, Jernej |
Stare, Katarina |
Božič, Dane, farmacevt |
Injac, Rade |
Dreu, Rok
Teme
delivery device |
design of experiments |
formulation |
in-vitro |
nasal spray |
suspension

vir: Journal of aerosol medicine and pulmonary drug delivery. - ISSN 1941-2711 (Vol. 30, no. 4, 2017, str. 230-246)



Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Faktor vpliva
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Grmaš, Jernej | 50110 |
Stare, Katarina | 28339 |
Božič, Dane, farmacevt | ![]() |
Injac, Rade | 30616 |
Dreu, Rok | 21455 |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema: