VSE knjižnice (vzajemna bibliografsko-kataložna baza podatkov COBIB.SI)
  • Sporadic hepatitis A virus PCR false-positive results observed during reflex testing of serum samples previously tested for Anti-HAV antibodies and caused by contamination with HAV RNA present in the reagents of the commercial Anti-HAV immunoassay [Elektronski vir]
    Lunar, Maja M., 1982- ...
    Hepatitis A diagnosis relies on serology and occasionally on hepatitis A virus (HAV) RNA detection. For timely diagnosis and the avoidance of drawing additional blood, molecular testing is often ... performed as reflex testing by using blood specimens that were initially sent for anti-HAV serology. Reflex molecular testing is preferably performed from different sample aliquots, but, for limited sample quantities, it uses samples that have been preprocessed in an immunoassay analyzer. In 2012, we first observed spo- radic HAV RNA-positive cases that were inconsistent with patients’ serological profiles and/ or medical histories, suggesting that occasional laboratory contamination was causing false-positive PCR results. Multiple external quality assurance (EQA) and laboratory sur- face contamination checks were performed, questionable specimens were tested with various HAV RNA tests, and follow-up serum/stool samples were collected. All contami- nation-check samples and samples from healthy individuals tested HAV RNA-negative, and the laboratory successfully passed all EQAs. The HAV RNA-positive results were re- producible with various HAV RNA assays. No patients seroconverted, and their follow-up samples were consistently HAV RNA-negative. Finally, a detailed review of testing protocols revealed a correlation between HAV RNA false positivity and preceding anti-HAV testing with the Cobas-e411 automated immunoassay analyzer. HAV RNA was detected in the Cobas-e411 anti-HAV reagents, with the HAV sequences matching those from the false- positive samples. Preceding anti-HAV testing using two other immunoassay analyzers did not result in subsequent HAV RNA false positivity during reflex testing. The Cobas-e411 pipetting procedure with a single pipette tip collecting samples and anti-HAV reagents contaminated the original sample with the HAV RNA that was present in the immunoas- say’s reagents, thereby resulting in HAV RNA false positivity during the reflex testing.
    Vir: Microbiology spectrum [Elektronski vir]. - ISSN 2165-0497 (Vol. 11, iss. 3, [article no.] e0012223, 2023, str. 1-6)
    Vrsta gradiva - e-članek ; neleposlovje za odrasle
    Leto - 2023
    Jezik - angleški
    COBISS.SI-ID - 151706883