VSE knjižnice (vzajemna bibliografsko-kataložna baza podatkov COBIB.SI)
  • Modeling of hydrogen behavior in a PWR nuclear power plant containment with the CONTAIN code
    Bobovnik, Gregor, 1978- ; Kljenak, Ivo
    Hydrogen behavior in the containment during a severe accident in a two-loop Westinghouse-type PWR nuclear power plant was simulated with the CONTAIN code. The accident was initiated with a cold-leg ... break of the reactor coolant system in a steam generator compartment. In the input model, the containment is represented with 34 cells. Beside hydrogen concentration, the containment atmosphere temperature and pressure and the carbon monoxide concentration were observed as well. Simulations were carried out for two different scenarios: with and without successful actuation of the containment spray system. The highest hydrogen concentration occurs in the containment dome and near the hydrogen release location in the early stages of the accident. Containment sprays do not have a significant effect on hydrogen stratification.
    Vir: Proceedings (Str. 313.1-313.8)
    Vrsta gradiva - prispevek na konferenci
    Leto - 2001
    Jezik - angleški
    COBISS.SI-ID - 16470823

vir: Proceedings (Str. 313.1-313.8)
loading ...
loading ...
loading ...