VSE knjižnice (vzajemna bibliografsko-kataložna baza podatkov COBIB.SI)
  • Experimental investigation of the shear force capacity of prismatic cross laminated timber beams [Elektronski vir]
    Danielsson, Henrik ...
    Experimental tests of Cross Laminated Timber (CLT) under in-plane beam loading conditions are presented. The influence of the element layup, the individual lamination width, and the beam overhang at ... the supports on the shear force capacity was investigated. All the CLT beams had the same gross cross section, and a 4-point-bending test setup was used. The experimentally determined load-bearing capacities are compared with the load-bearing capacities resulting from analytical methods proposed for structural design, focusing on shear failure in the crossing areas of flatwise bonded laminations (shear failure mode III). The test results indicate no or very small influence of the element layup and the lamination width on the shear force capacity. These results partly contradict the predictions of the proposed design methods. Of the three studied beam geometry parameters, the beam overhang at the support had the greatest influence on the load-bearing capacity.
    Vir: Engineering structures [Elektronski vir]. - ISSN 1873-7323 (Vol. 308, [article no.] 117889, Jun. 2023, str. 1-15)
    Vrsta gradiva - e-članek ; neleposlovje za odrasle
    Leto - 2024
    Jezik - angleški
    COBISS.SI-ID - 191865091