Test of three-storey confined masonry structure built from clay blocks and PU glue [Elektronski vir]Gams, Matija, gradbeništvo ...The paper presents an experimental test of a nearly full-scale three-storey model of a confined masonry structure. The walls were constructed using newly developed clay masonry blocks, with large ... holes filled with thermal insulation and polyurethane glue instead of mortar. In the construction, relatively thick 38 cm walls and large tie-columns with 25 cm × 25 cm plan dimensions. The test model was built as confined masonry according to Eurocode 8. The innovative materials and construction were developed for thermal efficiency and the test was intended to verify the structural response. The model, test setup, and test procedures are described, and the results of the tests are analysed. The building responded primarily in shear, and ultimately failed in the ground floor in a storey mechanism, but there was also substantial damage on the floor above. Due to the non-standard dimensions of the tie-columns and because masonry was thicker than the tie-columns, the in-plane loaded walls developed an interesting response mechanism in which protruding masonry sheared off. Although this did not significantly impact the overall response, it led to the earlier onset of the significant damage limit state of the structure. The model responded well with wide hysteretic loops and distributed damage, which indicated large energy dissipation capacity, and the response envelopes showed gradual strength deterioration after peak load. The response of the model was quantitatively estimated using the N2 method. Calculations showed that the tested model could withstand a design seismic load corresponding to a 0.21 g peak ground acceleration with significant damage and almost 0.52 g before collapsing. The overstrength was estimated at 1.71.Vir: Journal of building engineering [Elektronski vir]. - ISSN 2352-7102 (art. 109696, Letn. 91, 2024, 18 str.)Vrsta gradiva - e-članekLeto - 2024Jezik - angleškiCOBISS.SI-ID - 197310723
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Gams, Matija, gradbeništvo | 24339 |
Triller, Petra | 37502 |
Tomaževič, Miha | 00654 |
Jäger, Andreas, 1965- | ![]() |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema: