  • The influence of the space between the billets on the productivity of a continuous walking-beam furnace
    Jaklič, Anton, 1970- ; Kolenko, Tomaž ; Zupančič, Borut, 1952-
    This paper presents a study of the influence of the space between billets on the productivity of a continuous walking-beam furnace. The study was performed using a simulation model of a ... billet-reheating process for three different billet dimensions. The simulation model considered the exact geometry of the furnace enclosure, including the geometry of the billets inside the furnace. A view-factor matrix of the furnace enclosure was determined using the Monte Carlo method. The heat exchange between the furnace gas, the furnace wall and the billet's surface was calculated using a three-temperature model. The temperature of the furnace floor was determined using a heat-balance equation, and the heat conduction in the billets was calculated using the 3D finite-difference method. The model was validated using measurements from trailing thermocouples positioned in the test billet during the reheating process in the furnace.
    Vir: Applied thermal engineering. - ISSN 1359-4311 (Vol. 25, no. 5-6, 2005, str. 783-795)
    Vrsta gradiva - članek, sestavni del
    Leto - 2005
    Jezik - angleški
    COBISS.SI-ID - 374186

vir: Applied thermal engineering. - ISSN 1359-4311 (Vol. 25, no. 5-6, 2005, str. 783-795)