VSE knjižnice (vzajemna bibliografsko-kataložna baza podatkov COBIB.SI)
  • Determination of the applicability and limits of void and delamination detection in concrete structures using infrared thermography
    Cotič Smole, Patricia, 1987- ...
    Based on the results of the infrared thermography of 51 artificially created defects - voids and delaminations - in concrete, it was shown that it is possible to detect defects at depths that are ... equal or less than the defect size D using the thermal contrast method. By applying the phase contrast method, an increase of 50% in the maximum depth for a given defect size D was achieved. Delaminations containing thin air gaps were detected with the same success as much larger voids of the same cross section.
    Vir: NDT & E International. - ISSN 0963-8695 (Letn. 74, št. sept., 2015, str. 87-93)
    Vrsta gradiva - članek, sestavni del ; neleposlovje za odrasle
    Leto - 2015
    Jezik - angleški
    COBISS.SI-ID - 7065697
    DOI

vir: NDT & E International. - ISSN 0963-8695 (Letn. 74, št. sept., 2015, str. 87-93)