VSE knjižnice (vzajemna bibliografsko-kataložna baza podatkov COBIB.SI)
-
Comparison of biparametric versus multiparametric prostate MRI for the detection of extracapsular extension and seminal vesicle invasion in biopsy naïve patientsCaglič, Iztok ...Purpose: To compare biparametric MRI (bpMRI) with multiparametric MRI (mpMRI) staging accuracy in assessing extracapsular extension (ECE) and seminal vesicle invasion (SVI). Method: Biopsy-naïve ... patients undergoing 3 T-MRI before radical prostatectomy for clinically significant prostate cancer were included in this single-centre retrospective study. Two uroradiologists separately evaluated bpMRI and mpMRI for presence of ECE and SVI using a 5-point Likert scale (1: ECE/SVI highly unlikely, 5: ECE/SVI highly likely). Results: 110 men of median age 63 years and PSA 8.5 ng/mL were included. ECE and SVI was confirmed histologically in 71/110 (64.5 %) and 18/110 (16.4 %) patients, respectively. Sensitivity and specificity of bpMRI versus mpMRI for predicting ECE was 59.1 % and 87.2 % versus 66.2 % and 84.6 %, respectively. For SVI detection, the sensitivity and specificity for bpMRI versus mpMRI was 66.7 % and 92.4 % versus 83.3 % and 97.8 %, respectively. At an optimal cut-off Likert score ≥3 for ECE prediction, mpMRI area under the receiver operating curve (AUC) was 0.80 (95 % confidence interval (CI) 0.72-0.87) versus 0.78 (95 % CI 0.69-0.86) for bpMRI (p = 0.52) and for SVI, mpMRI AUC was 0.91 (95 % CI 0.84-0.96) versus 0.86 (95 % CI 0.78-0.92) for bpMRI (p = 0.02), respectively. Inter-reader agreement for both ECE and SVI prediction was substantial, with a marginally higher k-value for mpMRI (k range, 0.67-0.75) than bpMRI (k range, 0.65-0.69). Conclusions: Diagnostic performance of bpMRI and mpMRI was comparable for detection of ECE, however, mpMRI with contrast was superior for SVI detection and improved the inter-reader agreement. Keywords: Diffusion weighted imaging; Dynamic contrast enhancement; Magnetic resonance imaging; Prostate cancer; Tumour staging.Vir: European journal of radiology. - ISSN 0720-048X (Vol. 141, 2021, str. 1-109804-9-109804)Vrsta gradiva - članek, sestavni delLeto - 2021Jezik - angleškiCOBISS.SI-ID - 98207747
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Caglič, Iztok | 57398 |
Sushentsev, Nikita | |
Shah, Nimish | |
Warren, Anne Y. | |
Lamb, Benjamin W. | |
Barrett, Tristan |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema: