Analiza pretokov dihalne zmesi skozi krožne anestezijske dihalne sisteme in njihov vpliv na izsušenost zrnc absorberja CO2 = The analysis of fresh gas flow in a circle anaesthetic breathing system, and its influence on CO2 absorbent desiccationKrižmarić, Miljenko ; Manohin, Aleksander, 1946-202Background: If at the end of anaesthesia, the gases on the anaesthetic machineare not turned off, they continue to flow through the breathing circuitand may dry out the carbon dioxide absorbent in ... the absorber. At the beginning of the next anaesthetic procedure, the desiccated absorbent decomposes the volatile anaesthetic, resulting in the formation of toxic gas mixtures, which are dangerous for the patient. In such circumstances, the measured level of the volatile anaesthesic in the breathing circuit differs from the selected value. In the paper, we analyse potentially dangerous possible directions of continuous flow of fresh gas mixture in different anaesthetic breathing circuits. Methods: In the first part of the study, we simulated the continuous flow of gases in a Sulla anaesthesia machine using anexperimental method in a simulation setting. In the second part, we analysedwhether a retrograde flow through the absorber was possible in a convential anaesthetic breathing circuit and in the Fabius GS, Cato, Julian and Primus circuits with the Y-piece connector open or closed. Information on users' requests for maintenance services due to discrepancies between the desired and measured levels of the volatile anaesthetic in the breathing circuit were obtained from the manufacturer's local servicing agent. Results: In a Draeger ISO 8 circle system (Sulla anaesthetic machine) with a standard gas supply connector, a retrograde flow is not possible. If the Y-piece connector is left open, the gases are vented to the outside via the absorber and the inspiratory tube. If the Y-piece connector is closed or open, the absorbent in the canister dries because of the continuous flow of gas. A retrograde flow is possible only in those Sulla anaestheticmachines where the fresh gas inlet is located below the inspiratory valve. (Abstract truncated at2000 characters).Vir: Zdravniški vestnik : glasilo Slovenskega zdravniškega društva = Slovenian medical journal = journal of Slovenian Medical Association. - ISSN 1318-0347 (Letn. 81, št. 4, 2012, str. 341-348)Vrsta gradiva - članek, sestavni delLeto - 2012Jezik - slovenskiCOBISS.SI-ID - 29812441
vir: Zdravniški vestnik : glasilo Slovenskega zdravniškega društva = Slovenian medical journal = journal of Slovenian Medical Association. - ISSN 1318-0347 (Letn. 81, št. 4, 2012, str. 341-348)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Križmarić, Miljenko | 25641 |
Manohin, Aleksander, 1946-202 | 02086 |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema:
Naročanje gradiva za izposojo v čitalnice
Naročanje kopij člankov
Urnik dostave gradiva z oznako DS v signaturi