Influence of the Integral Quality Monitor transmission detector on high energy photon beams : a multi-centre studyCasar, Božidar ...The influence of the Integral Quality Monitor (IQM) transmission detector on photon beam properties was evaluated in a preclinical phase, using data from nine participating centres: (i) the change of ... beam quality (beam hardening), (ii) the influence on surface dose, and (iii) the attenuation of the IQM detector. METHODS: For 6 different nominal photon energies (4 standard, 2 FFF) and square field sizes from 1%1cm2 to 20%20cm2, the effect of IQM on beam quality was assessed from the PDD20,10 values obtained from the percentage dose depth (PDD) curves, measured with and without IQM in the beam path. The change in surface dose with/without IQM was assessed for all available energies and field sizes from 4%4cm2 to 20%20cm2. The transmission factor was calculated by means of measured absorbed dose at 10cm depth for all available energies and field sizes. RESULTS: (i) A small (0.11-0.53%) yet statistically significant beam hardening effect was observed, depending on photon beam energy. (ii) The increase in surface dose correlated with field size (p<0.01) for all photon energies except for 18MV. The change in surface dose was smaller than 3.3% in all cases except for the 20%20cm2 field and 10MV FFF beam, where it reached 8.1%. (iii) For standard beams, transmission of the IQM showed a weak dependence on the field size, and a pronounced dependence on the beam energy (0.9412 for 6MV to 0.9578 for 18MV and 0.9440 for 6MV FFF; 0.9533 for 10MV FFF). CONCLUSIONS: The effects of the IQM detector on photon beam properties were found to be small yet statistically significant. The magnitudes of changes which were found justify treating IQM either as tray factors within the treatment planning system (TPS) for a particular energy or alternatively as modified outputs for specific beam energy of linear accelerators, which eases the introduction of the IQM into clinical practice.Vir: Zeitschrift für medizinische Physik. - ISSN 0939-3889 (Vol. 27, no. 3, Sep. 2017, str. 232-242)Vrsta gradiva - članek, sestavni delLeto - 2017Jezik - angleškiCOBISS.SI-ID - 2687099
Avtor
Casar, Božidar |
Pasler, Marlies |
Wegener, Sonja |
Hoffman, David |
Talamonti, Cinzia |
Qian, Jianguo |
Méndez Carot, Ignasi |
Brojan, Denis |
Perrin, Bruce |
Kusters, Martijn |
Peterlin, Primož
Teme
transmisijski detektor |
neposredno spremljanje doze |
kakovost |
linearni pospeševalnik |
trdota žarka |
transmission detector |
on-line dose monitoring |
quality assurance |
linear accelerator |
beam hardening
![loading ... loading ...](themes/default/img/ajax-loading.gif)
vir: Zeitschrift für medizinische Physik. - ISSN 0939-3889 (Vol. 27, no. 3, Sep. 2017, str. 232-242)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Casar, Božidar | 15973 |
Pasler, Marlies | ![]() |
Wegener, Sonja | ![]() |
Hoffman, David | ![]() |
Talamonti, Cinzia | ![]() |
Qian, Jianguo | ![]() |
Méndez Carot, Ignasi | 39019 |
Brojan, Denis | ![]() |
Perrin, Bruce | ![]() |
Kusters, Martijn | ![]() |
Peterlin, Primož | 12531 |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Mesto prevzema | Status gradiva | Rezervacija |
---|
Prosimo, počakajte trenutek.