Grasp55 is a ubiquitous Golgi stacking protein involved in autophagy, protein trafficking, and glucose deprivation sensing. The function of Grasp55 in protein trafficking has been attributed to its ...PDZ-mediated interaction with the C-terminal PDZ-binding motifs of protein cargos. We have recently shown that such an interaction occurs between Grasp55 and the adhesion molecule Jam-C, which plays a central role in stemness maintenance of hematopoietic and spermatogenic cells. Accordingly, we have found that
-deficient mice suffer from spermatogenesis defects similar to
knockout mice. However, whether Grasp55 is involved in the maintenance of immunohematopoietic homeostasis through regulation of protein transport and Jam-C expression remains unknown. In this study, we show that
deficiency does not affect hematopoietic stem cell differentiation, engraftment, or mobilization, which are known to depend on expression of Grasp55-dependent protein cargos. In contrast, using an Myc-dependent leukemic model addicted to autophagy, we show that knockdown of Grasp55 in leukemic cells reduces spleen and bone marrow tumor burden upon i.v. leukemic engraftment. This is not due to reduced homing of Grasp55-deficient cells to these organs but to increased spontaneous apoptosis of Grasp55-deficient leukemic cells correlated with increased sensitivity of the cells to glucose deprivation. These results show that Grasp55 plays a role in Myc-transformed hematopoietic cells but not in normal hematopoietic cells in vivo.
Abstract Purpose To describe the characteristics of reversible focal pleural thickenings (PTs) mimicking real plaques, that firstly suggest asbestos exposure or pleural metastasis; to propose an ...imaging strategy and propose an explanation for their mechanism of formation. Patients and methods Retrospective review of data from 19 patients with PTs fitting the description of pleural plaques at chest computed tomography (CT) and presenting modifications (clearance or appearance) of at least one PT at an additional chest examination in prone position. Results A total of 152 PTs were recorded on the first chest CT examinations with a range of two to 19 pleural opacities per patient. All PTs had a posterior distribution in the lower lobes. On the additional acquisitions, 144 PTs disappeared. Seventeen patients presented complete regression of PTs and two patients presented persistence of eight PTs. Conclusion Additional low dose acquisition in prone position should be performed in all patients presenting with focal PT in a dependent and basal location. This may allow to exclude a pleural plaque in case of asbestos exposure but also a pleural metastasis in oncologic patients. These reversible dependent PTs could be related to physiological focal accumulation of lymphatic fluid in subpleural area.
3D silicon pixel sensors: Recent test beam results Hansson, P.; Balbuena, J.; Barrera, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2011, Volume:
628, Issue:
1
Journal Article
Peer reviewed
The 3D silicon sensors aimed for the ATLAS pixel detector upgrade have been tested with a high energy pion beam at the CERN SPS in 2009. Two types of sensor layouts were tested: full-3D assemblies ...fabricated in Stanford, where the electrodes penetrate the entire silicon wafer thickness, and modified-3D assemblies fabricated at FBK-irst with partially overlapping electrodes. In both cases three read-out electrodes are ganged together to form pixels of dimension
50
×
400
μ
m
2
. Data on the pulse height distribution, tracking efficiency and resolution were collected for various particle incident angles, with and without a 1.6
T magnetic field. Data from a planar sensor of the type presently used in the ATLAS detector were used at the same time to give comparison.
To compare thin-section computed tomographic (CT) scans obtained during suspended end expiration with helical CT scans obtained during continuous expiration for the assessment of air trapping.
...Forty-nine patients with an airway disease were examined with suspended-end-expiration CT after a 6-8-second expiratory maneuver, which was followed with continuous-expiration CT during a 10-second expiratory maneuver. The extent of expiratory air-trapping areas was calculated by two observers by using a semiquantitative grid score. The relative decrease in attenuation in the areas of air trapping was evaluated with a visual continuous-scale score.
Air trapping was noted in 36 and 35 patients with continuous-expiration CT and with suspended-end-inspiration CT, respectively. The extents of and relative attenuation decreases in air-trapping areas in patients with air-trapping areas on at least one expiratory CT scan increased significantly in scans obtained with continuous-expiration CT compared with those obtained with suspended-end-expiration CT, respectively, with mean extent scores of 0.24 +/- 0.20 (SD) and 0.18 +/- 0.20 (paired t test, P: =.001) respectively, and with mean relative contrast decrease scores of 0.35 +/- 0.23 and 0.27 +/- 0.23 (paired t test, P: =.007), respectively.
When suspended-end-expiration CT images are ambiguous, complementary continuous-expiration CT can be used to improve the conspicuity and apparent extent of air trapping.
A
bstract
The factor of four increase in the LHC luminosity, from 0
.
5
×
10
34
cm
−
2
s
−
1
to 2
.
0
×
10
34
cm
−
2
s
−
1
, and the corresponding increase in pile-up collisions during the 2015–2018 ...data-taking period, presented a challenge for the ATLAS trigger, particularly for those algorithms that select events with missing transverse momentum. The output data rate at fixed threshold typically increases exponentially with the number of pile-up collisions, so the legacy algorithms from previous LHC data-taking periods had to be tuned and new approaches developed to maintain the high trigger efficiency achieved in earlier operations. A study of the trigger performance and comparisons with simulations show that these changes resulted in event selection efficiencies of
>
98% for this period, meeting and in some cases exceeding the performance of similar triggers in earlier run periods, while at the same time keeping the necessary bandwidth within acceptable limits.
Molecular diffusion and microcirculation in the capillary network result in a distribution of phases in a single voxel in the presence of magnetic field gradients. This distribution produces a ...spin-echo attenuation. The authors have developed a magnetic resonance (MR) method to image such intravoxel incoherent motions (IVIMs) by using appropriate gradient pulses. Images were generated at 0.5 T in a high-resolution, multisection mode. Diffusion coefficients measured on images of water and acetone phantoms were consistent with published values. Images obtained in the neurologic area from healthy subjects and patients were analyzed in terms of an apparent diffusion coefficient (ADC) incorporating the effect of all IVIMs. Differences were found between various normal and pathologic tissues. The ADC of in vivo water differed from the diffusion coefficient of pure water. Results were assessed in relation to water compartmentation in biologic tissues (restricted diffusion) and tissue perfusion. Nonuniform slow flow of cerebrospinal fluid appeared as a useful feature on IVIM images. Observation of these motions may significantly extend the diagnostic capabilities of MR imaging.