Modern service-oriented enterprise systems have increasingly complex and dynamic loosely-coupled architectures that often exhibit poor performance and resource efficiency and have high operating ...costs. This is due to the inability to predict at run-time the effect of workload changes on performance-relevant application-level dependencies and adapt the system configuration accordingly. Architecture-level performance models provide a powerful tool for performance prediction, however, current approaches to modeling the context of software components are not suitable for use at run-time. In this paper, we analyze typical online performance prediction scenarios and propose a performance meta-model for (i) expressing and resolving parameter and context dependencies, (ii) modeling service abstractions at different levels of granularity and (iii) modeling the deployment of software components in complex resource landscapes. The presented meta-model is a subset of the Descartes Meta-Model (DMM) for online performance prediction, specifically designed for use in online scenarios. We motivate and validate our approach in the context of realistic and representative online performance prediction scenarios based on the SPECjEnterprise2010 standard benchmark.
•Discussion between online and offline performance prediction scenarios.•Modeling performance-relevant service behavior at different levels of detail.•Modeling parameter dependencies specifically for use at run-time.•Evaluation based on the SPECjEnterprise2010 standard benchmark.
We present a measurement of the atmospheric neutrino oscillation parameters using three years of data from the IceCube Neutrino Observatory. The DeepCore infill array in the center of IceCube enables ...the detection and reconstruction of neutrinos produced by the interaction of cosmic rays in Earth's atmosphere at energies as low as ∼5 GeV. That energy threshold permits measurements of muon neutrino disappearance, over a range of baselines up to the diameter of the Earth, probing the same range of L/E_{ν} as long-baseline experiments but with substantially higher-energy neutrinos. This analysis uses neutrinos from the full sky with reconstructed energies from 5.6 to 56 GeV. We measure Δm_{32}^{2}=2.31_{-0.13}^{+0.11}×10^{-3} eV^{2} and sin^{2}θ_{23}=0.51_{-0.09}^{+0.07}, assuming normal neutrino mass ordering. These results are consistent with, and of similar precision to, those from accelerator- and reactor-based experiments.
Full text
Available for:
CMK, CTK, FMFMET, NUK, UL
Two-dimensional infrared spectroscopy (2D-IR) was used to investigate the sensitivity of a vibrational mode to spectral diffusion on the nanometer length scale. A confined volume within a porous ...silica nanoparticle was used as the model system. Utilizing a novel grafting technique, silane probes were covalently secured to the pore surface for a series of templated mesoporous silica nanoparticles with variable pore sizes. 2D-IR measurements determined that isopropanol exhibited two dominant time scales of ultrafast motions within the pores with time scales of a few picoseconds and tens of picoseconds. The unique perspective of the probe on a surface revealed that the vibrational dynamics of the reporting mode were perturbed by molecules up to ∼5 nm away. The data were modeled well by a 1/d 2 distance dependence for the coupling of solvent dynamics to frequency fluctuations and a logistic radial distribution of fast and slow dynamic populations.
Abstract
We investigate the masses of ‘retired A stars’ using asteroseismic detections on seven low-luminosity red-giant and sub-giant stars observed by the NASA Kepler and K2 missions. Our aim is to ...explore whether masses derived from spectroscopy and isochrone fitting may have been systematically overestimated. Our targets have all previously been subject to long-term radial velocity observations to detect orbiting bodies, and satisfy the criteria used by Johnson et al. to select survey stars which may have had A-type (or early F-type) main-sequence progenitors. The sample actually spans a somewhat wider range in mass, from ≈ 1 M⊙ up to ≈ 1.7 M⊙. Whilst for five of the seven stars the reported discovery mass from spectroscopy exceeds the mass estimated using asteroseismology, there is no strong evidence for a significant, systematic bias across the sample. Moreover, comparisons with other masses from the literature show that the absolute scale of any differences is highly sensitive to the chosen reference literature mass, with the scatter between different literature masses significantly larger than reported error bars. We find that any mass difference can be explained through use of different constraints during the recovery process. We also conclude that underestimated uncertainties on the input parameters can significantly bias the recovered stellar masses, which may have contributed to the controversy on the mass scale for retired A stars.
Tetrahydropyran-2-methanol undergoes selective C–O–C hydrogenolysis to produce 1,6-hexanediol using a bifunctional RhRe (reducible metal with an oxophilic promoter) catalyst supported on Vulcan XC-72 ...carbon (VXC) with >90% selectivity. This RhRe/VXC catalyst is stable over 40 h of reaction in a continuous flow fixed bed reactor. The hydrogenolysis activity of RhRe/VXC is two orders-of-magnitude higher than that of RhRe supported on Norit Darco 12X40 activated carbon (NDC). STEM–EDS analysis reveals that, compared to the RhRe/VXC catalyst, the Re and Rh component metals are segregated on the surface of the low activity RhRe/NDC catalyst, suggesting that Rh and Re in close proximity (“bimetallic” particles) are required for an active hydrogenolysis catalyst. Differences in metal distribution on the carbon surfaces are, in turn, linked to the properties of the carbons: NDC has both a higher surface area and surface oxygen content. The low areal density of Rh and Re precursors on the high area NDC and/or interactions of the precursors with its O functional groups may interfere with the formation of the bimetallic species required for an active catalyst.
Recently, a real-time PCR assay known as photo-induced electron transfer (PET)-PCR which relies on self-quenching primers for the detection of Plasmodium spp. and Plasmodium falciparum was described. ...PET-PCR assay was found to be robust, and easier to use when compared to currently available real-time PCR methods. The potential of PET-PCR for molecular detection of malaria parasites in a nationwide malaria community survey in Haiti was investigated.
DNA from the dried blood spots was extracted using QIAGEN methodology. All 2,989 samples were screened using the PET-PCR assay in duplicate. Samples with a cycle threshold (CT) of 40 or less were scored as positive. A subset of the total samples (534) was retested using a nested PCR assay for confirmation. In addition, these same samples were also tested using a TaqMan-based real-time PCR assay.
A total of 12 out of the 2,989 samples screened (0.4%) were found to be positive by PET-PCR (mean CT value of 35.7). These same samples were also found to be positive by the nested and TaqMan-based methods. The nested PCR detected an additional positive sample in a subset of 534 samples that was not detected by either PET-PCR or TaqMan-based PCR method.
While the nested PCR was found to be slightly more sensitive than the PET-PCR, it is not ideal for high throughput screening of samples. Given the ease of use and lower cost than the nested PCR, the PET-PCR provides an alternative assay for the rapid screening of a large number of samples in laboratory settings.
Background Accelerometers were traditionally worn on the hip to estimate energy expenditure (EE) during physical activity but are increasingly replaced by products worn on the wrist to enhance wear ...compliance, despite potential compromises in EE estimation accuracy. In the older population, where the prevalence of hearing loss is higher, a new, integrated option may arise. Thus, this study aimed to investigate the accuracy and precision of EE estimates using an accelerometer integrated into a hearing aid and compare its performance with sensors simultaneously worn on the wrist and hip. Methods Sixty middle-aged to older adults (average age 64.0 ± 8.0 years, 48% female) participated. They performed a 20-min resting energy expenditure measurement (after overnight fast) followed by a standardized breakfast and 13 different activities of daily living, 12 of them were individually selected from a set of 35 activities, ranging from sedentary and low intensity to more dynamic and physically demanding activities. Using indirect calorimetry as a reference for the metabolic equivalent of task (MET), we compared the EE estimations made using a hearing aid integrated device (Audéo) against those of a research device worn on the hip (ZurichMove) and consumer devices positioned on the wrist (Garmin and Fitbit). Class-estimated and class-known models were used to evaluate the accuracy and precision of EE estimates via Bland-Altman analyses. Results The findings reveal a mean bias and 95% limit of agreement for Audéo (class-estimated model) of −0.23 ± 3.33 METs, indicating a slight advantage over wrist-worn consumer devices (Garmin: −0.64 ± 3.53 METs and Fitbit: −0.67 ± 3.40 METs). Class-know models reveal a comparable performance between Audéo (−0.21 ± 2.51 METs) and ZurichMove (−0.13 ± 2.49 METs). Sub-analyses show substantial variability in accuracy for different activities and good accuracy when activities are averaged over a typical day's usage of 10 h (+61 ± 302 kcal). Discussion This study shows the potential of hearing aid-integrated accelerometers in accurately estimating EE across a wide range of activities in the target demographic, while also highlighting the necessity for ongoing optimization efforts considering precision limitations observed across both consumer and research devices.