  • Implant Survival and Functi... Implant Survival and Function Ten Years After Kinematically Aligned Total Knee Arthroplasty
    Howell, Stephen M.; Shelton, Trevor J.; Hull, Maury L. The Journal of arthroplasty, December 2018, 2018-12-00, 20181201, Volume: 33, Issue: 12
    Journal Article
    Peer reviewed

    Alignment in the varus or valgus outlier range of the tibial component, knee, and limb might adversely affect the long-term results of kinematically aligned total knee arthroplasty (TKA) particularly ...
Full text
Available for: UL
2.
  • Coordinate system requireme... Coordinate system requirements to determine motions of the tibiofemoral joint free from kinematic crosstalk errors
    Hull, Maury L. Journal of biomechanics, 08/2020, Volume: 109
    Journal Article
    Peer reviewed

    The relative rigid body motions between the femur and the tibia (termed tibiofemoral kinematics) during flexion activities can provide an objective measure of knee function. Clinically meaningful ...
Full text
Available for: UL
3.
  • Does A Kinematically Aligne... Does A Kinematically Aligned Total Knee Arthroplasty Restore Function Without Failure Regardless of Alignment Category?
    Howell, Stephen M.; Howell, Stacey J.; Kuznik, Kyle T. ... Clinical orthopaedics and related research, 03/2013, Volume: 471, Issue: 3
    Journal Article
    Peer reviewed
    Open access

    Background Kinematically aligned TKA restores function by aligning the femoral and tibial components to the normal or prearthritic joint lines of the knee. However, aligning the components to the ...
Full text
Available for: UL

PDF
4.
  • Native Knee Laxities at 0°,... Native Knee Laxities at 0°, 45°, and 90° of Flexion and Their Relationship to the Goal of the Gap-Balancing Alignment Method of Total Knee Arthroplasty
    Howell, Stephen M., MD; Hull, Maury L., PhD; Roth, Joshua D., MS Journal of bone and joint surgery. American volume, 2015-October-21, Volume: 97, Issue: 20
    Journal Article
    Peer reviewed

    Background Gap-balancing is an alignment method for total knee arthroplasty with the goal of creating uniform tension in the periarticular soft-tissue restraints and equal laxities throughout the arc ...
Full text
Available for: UL
5.
  • Does Calipered Kinematicall... Does Calipered Kinematically Aligned TKA Restore Native Left to Right Symmetry of the Lower Limb and Improve Function?
    Nedopil, Alexander J.; Singh, Avreeta K.; Howell, Stephen M. ... The Journal of arthroplasty, February 2018, 2018-02-00, 20180201, Volume: 33, Issue: 2
    Journal Article
    Peer reviewed

    Kinematically aligned total knee arthroplasty (KA TKA) strives to restore the native left to right symmetry of the lower limb; however, the reproducibility of achieving this target is unknown. The ...
Full text
Available for: UL
6.
  • Significantly better precision with new machine learning versus manual image registration software in processing images from single-plane fluoroscopy to determine tibiofemoral kinematics following total knee replacement
    Pourtabib, Joseph; Hull, Maury L Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 238, Issue: 3
    Journal Article
    Peer reviewed

    One common method to determine tibiofemoral kinematics following total knee replacement (TKR) is to capture single-plane fluoroscopic images of a patient activity and determine anterior-posterior ...
Check availability
7.
  • Accurate alignment and high... Accurate alignment and high function after kinematically aligned TKA performed with generic instruments
    Howell, Stephen M.; Papadopoulos, Stelios; Kuznik, Kyle T. ... Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 10/2013, Volume: 21, Issue: 10
    Journal Article
    Peer reviewed

    Purpose Performing kinematically aligned total knee arthroplasty (TKA) with generic instruments is less costly than patient-specific instrumentation; however, the alignment and function with this new ...
Full text
Available for: FSPLJ, UL
8.
  • Reoperation, Implant Surviv... Reoperation, Implant Survival, and Clinical Outcome After Kinematically Aligned Total Knee Arthroplasty: A Concise Clinical Follow-Up at 16 Years
    Howell, Stephen M.; Akhtar, Muzammil; Nedopil, Alexander J. ... The Journal of arthroplasty, 03/2024, Volume: 39, Issue: 3
    Journal Article
    Peer reviewed

    The preceding study reported a 10-year follow-up of 222 kinematically aligned total knee arthroplasties (TKA) performed in 217 patients in 2007. As 35% of tibial components and 8% of limbs were in ...
Full text
Available for: UL
9.
  • Negligible effect of surgeo... Negligible effect of surgeon experience on the accuracy and time to perform unrestricted caliper verified kinematically aligned TKA with manual instruments
    Howell, Stephen M.; Nedopil, Alexander J.; Hull, Maury L. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 09/2022, Volume: 30, Issue: 9
    Journal Article
    Peer reviewed
    Open access

    Purpose Surgeons performing total knee arthroplasty (TKA) are interested in the accuracy and time it takes to make the four femoral resections that determine the setting of the femoral component. A ...
Full text
Available for: FSPLJ, UL
10.
  • The posterolateral upslope ... The posterolateral upslope of a low-conforming insert blocks the medial pivot during a deep knee bend in TKA: a comparative analysis of two implants with different insert conformities
    Delman, Connor M.; Ridenour, Delaney; Howell, Stephen M. ... Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 09/2023, Volume: 31, Issue: 9
    Journal Article
    Peer reviewed

    Purpose Tibial insert conformity in total knee arthroplasty (TKA) is of interest due to the potential effect on tibiofemoral kinematics. This study determined differences in anterior–posterior ...