The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is ...smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c^{2} using 1.4×10^{4} kg day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
Full text
Available for:
CMK, CTK, FMFMET, NUK, UL
Background. Use of the heptavalent pneumococcal conjugate vaccine (PCV-7 Prevnar) has been associated with decreased a incidence of invasive pneumococcal disease (IPD) among children in the United ...States. Methods. Cases of IPD in children <18 years of age insured by or receiving health care from Intermountain Health Care during 1996–2003 were identified. Isolates of S. pneumoniae from children with IPD treated at Primary Children's Medical Center (PCMC; Salt Lake City, UT) during 1997–2003 were serogrouped. Temporal trends of IPD, serogroup distribution of pneumococci, and antibiotic resistance among pneumococci were analyzed. Results. A total of 1535 cases of IPD were identified. The rate of IPD decreased 27% after the introduction of PCV7. Among children with IPD who were cared for at PCMC, disease in 73% was caused by PCV7 serogroups in 1997–2000, compared with 50% in 2001–2003 (P < .001), and the percentage of isolates resistant to penicillin decreased from 34% in 1997–2000 to 22% in 2001–2003 (P = .04). The percentage of IPD cases that were empyema increased from 16% to 30% (P = .015), and the percentage of severe cases of IPD increased from 57% to 71% (P = .026). Children with IPD due to non-PCV7 serogroups were older, were more likely to have parapneumonic empyema, and had longer hospital stays. Conclusions. The incidence of IPD in the IMW decreased by 27% after the introduction of the PCV7 vaccine. During the postvaccine period (2001–2003), there were significant decreases in the proportion of cases of IPD caused by PCV7 and antibiotic-resistant serogroups. These benefits were accompanied by a significant increase in the proportion of IPD cases due to non-PCV7 serogroups, with increases in the incidence of empyema and severe IPD.
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. ...Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment’s high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.