The manipulation of quantum states of light
holds the potential to enhance searches for fundamental physics. Only recently has the maturation of quantum squeezing technology coincided with the ...emergence of fundamental physics searches that are limited by quantum uncertainty
. In particular, the quantum chromodynamics axion provides a possible solution to two of the greatest outstanding problems in fundamental physics: the strong-CP (charge-parity) problem of quantum chromodynamics
and the unknown nature of dark matter
. In dark matter axion searches, quantum uncertainty manifests as a fundamental noise source, limiting the measurement of the quadrature observables used for detection. Few dark matter searches have approached this limit
, and until now none has exceeded it. Here we use vacuum squeezing to circumvent the quantum limit in a search for dark matter. By preparing a microwave-frequency electromagnetic field in a squeezed state and near-noiselessly reading out only the squeezed quadrature
, we double the search rate for axions over a mass range favoured by some recent theoretical projections
. We find no evidence of dark matter within the axion rest energy windows of 16.96-17.12 and 17.14-17.28 microelectronvolts. Breaking through the quantum limit invites an era of fundamental physics searches in which noise reduction techniques yield unbounded benefit compared with the diminishing returns of approaching the quantum limit.
The Cryogenic Dark Matter Search Experiment (CDMS) and its successor, SuperCDMS, have had a long history of establishing world-leading upper limits on the interaction of Weakly Interacting Massive ...Particles (WIMPs) with standard model nucleons. SuperCDMS uses arrays of cryogenic germanium detectors to achieve excellent discrimination between the nuclear recoils expected for WIMP interactions and radioactively produced electron recoils through the collection of ionization and athermal phonons. Recent analyses of the data collected from the current installation of Interleaved Z-Sensitive Ionization and Phonon (iZIP) detectors have probed new regions of the WIMP parameter space, particularly in the region of low-mass WIMP interactions. This paper will discuss the current work of the SuperCDMS collaboration.
X-ray phase contrast imaging has overcome the limitations of X-ray absorption imaging in many fields. Particular effort has been directed towards developing phase retrieval methods: These reveal ...quantitative information about a sample, which is a requirement for performing X-ray phase tomography, allows material identification and better distinction between tissue types, etc. Phase retrieval seems impossible with conventional X-ray sources due to their low spatial coherence. In the only previous example where conventional sources have been used, collimators were employed to produce spatially coherent secondary sources. We present a truly incoherent phase retrieval method, which removes the spatial coherence constraints and employs a conventional source without aperturing, collimation, or filtering. This is possible because our technique, based on the pixel edge illumination principle, is neither interferometric nor crystal based. Beams created by an X-ray mask to image the sample are smeared due to the incoherence of the source, yet we show that their displacements can still be measured accurately, obtaining strong phase contrast. Quantitative information is extracted from only two images rather than a sequence as required by several coherent methods. Our technique makes quantitative phase imaging and phase tomography possible in applications where exposure time and radiation dose are critical. The technique employs masks which are currently commercially available with linear dimensions in the tens of centimeters thus allowing for a large field of view. The technique works at high photon energy and thus promises to deliver much safer quantitative phase imaging and phase tomography in the future.
This pilot study examines the correlation of X-ray diffraction (XRD) measurements with the histopathological analysis of breast tissue. Eight breast cancer samples were investigated. Each sample ...contained a mixture of normal and cancerous tissues. In total, 522 separate XRD measurements were made at different locations across the samples (8 in total). The resulting XRD spectra were subjected to principal component analysis (PCA) in order to determine if there were any distinguishing features that could be used to identify different tissue components. 99.0% of the variation between the spectra were described by the first two principal components (PC). Comparing the location of points in PC space with the classification determined by histopathology indicated correlation between the shape/magnitude of the XRD spectra and the tissue type. These results are encouraging and suggest that XRD could be used for the intraoperative or postoperative classification of bulk tissue samples.
•Non-destructive screening of unpackaged and packaged tablet formulations.•High accuracy of quantification using multivariate calibration methods.•Data pre-treatment prior to modelling and prediction ...not required.•Improved prediction accuracy compared to angular dispersive X-ray diffraction and comparable to Raman spectroscopy.
A system using energy-dispersive X-ray diffraction (EDXRD) has been developed and tested using multivariate calibration for the quantitative analysis of tablet-form mixtures of common pharmaceutical ingredients. A principal advantage of EDXRD over the more traditional and common angular dispersive X-ray diffraction technique (ADXRD) is the potential of EDXRD to analyse tablets within their packaging, due to the higher energy X-rays used.
In the experiment, a series of caffeine, paracetamol and microcrystalline cellulose mixtures were prepared and pressed into tablets. EDXRD profiles were recorded on each sample and a principal component analysis (PCA) was carried out in both unpackaged and packaged scenarios. In both cases the first two principal components explained >98% of the between-sample variance. The PCA projected the sample profiles into two dimensional principal component space in close accordance to their ternary mixture design, demonstrating the discriminating potential of the EDXRD system.
A partial least squares regression (PLSR) model was built with the samples and was validated using leave-one-out cross-validation. Low prediction errors of between 2% and 4% for both unpackaged and packaged tablets were obtained for all three chemical compounds. The prediction capability through packaging demonstrates a truly non-destructive method for quantifying tablet composition and demonstrates good potential for EDXRD to be applied in the field of counterfeit medicine screening and pharmaceutical quality control.