LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above
1.4
×
10
-
48
cm
2
for a WIMP mass of
40
GeV
/
c
2
and a
1000
days
...exposure. LZ achieves this sensitivity through a combination of a large
5.6
t
fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
The visible world is founded on the proton, the only composite building block of matter that is stable in nature. Consequently, understanding the formation of matter relies on explaining the dynamics ...and the properties of the proton's bound state. A fundamental property of the proton involves the response of the system to an external electromagnetic field. It is characterized by the electromagnetic polarizabilities
that describe how easily the charge and magnetization distributions inside the system are distorted by the electromagnetic field. Moreover, the generalized polarizabilities
map out the resulting deformation of the densities in a proton subject to an electromagnetic field. They disclose essential information about the underlying system dynamics and provide a key for decoding the proton structure in terms of the theory of the strong interaction that binds its elementary quark and gluon constituents. Of particular interest is a puzzle in the electric generalized polarizability of the proton that remains unresolved for two decades
. Here we report measurements of the proton's electromagnetic generalized polarizabilities at low four-momentum transfer squared. We show evidence of an anomaly to the behaviour of the proton's electric generalized polarizability that contradicts the predictions of nuclear theory and derive its signature in the spatial distribution of the induced polarization in the proton. The reported measurements suggest the presence of a new, not-yet-understood dynamical mechanism in the proton and present notable challenges to the nuclear theory.
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4 × 10-48 cm2 for a WIMP mass of 40 GeV/c 2 and a 1000 d ...exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and be spoke detector systems to assay scintillator are presented.
The LUX-ZEPLIN (LZ) experiment Akimov, D.Yu; Angelides, N.; Araújo, H.M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2020, Volume:
953, Issue:
C
Journal Article
Peer reviewed
Open access
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time ...projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850’ level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
The purpose of this study was to describe the spectrum of radiologic and pathologic manifestations of calcific tendinitis involving bone.
We retrospectively reviewed 50 cases of calcific tendinitis ...involving underlying bone. Clinical data reviewed included patient age and sex and lesion location. Images reviewed included radiographs (n = 44), CT scans (n = 13), MRIs (n = 16), and bone scintigrams (n = 13). Radiologic examinations were evaluated for the presence of cortical erosion, periosteal reaction, and marrow extension. Pathology confirmation was available in 37 cases.
The average age of patients was 50 years (range, 16-82 years), with 29 female patients (58%). Calcific tendinitis with associated bone involvement was seen most commonly in the femur (40%) and the humerus (40%). Concretions were most commonly solid-appearing (50%). Cortical erosion was the most common manifestation of osseous involvement (78% of cases). Marrow involvement was shown in 18 (36%) of 50 cases. Marrow extension was most commonly seen in the lesser and greater tuberosities of the humerus, which accounted for 61% (11/18) of cases. Focal increased radionuclide uptake was seen in 13 (100%) of 13 cases.
Calcific tendinitis presenting with osseous destruction, marrow changes, and soft-tissue calcifications may be confused with neoplasm both radiologically and pathologically. Recognition of the atypical presentation of this common disease may prevent unnecessary biopsy.
The LUX-ZEPLIN dark matter search aims to achieve a sensitivity to the WIMP-nucleon spin-independent cross-section down to (1–2)×10−12 pb at a WIMP mass of 40 GeV/c2. This paper describes the ...simulations framework that, along with radioactivity measurements, was used to support this projection, and also to provide mock data for validating reconstruction and analysis software. Of particular note are the event generators, which allow us to model the background radiation, and the detector response physics used in the production of raw signals, which can be converted into digitized waveforms similar to data from the operational detector. Inclusion of the detector response allows us to process simulated data using the same analysis routines as developed to process the experimental data.
Recently, we reported the localization of a gene for transient neonatal diabetes mellitus (TNDM), a rare form of childhood diabetes, to an approximately 5.4 Mb region of chromosome 6q24. We have also ...shown that TNDM is associated with both paternal uniparental disomy (UPD) of chromosome 6 and paternal duplications of the critical region. The sequencing of P1-derived artificial chromosome clones from within the region of interest has allowed us to further localize the gene and to investigate the methylation status of the region. The gene is now known to reside in a 300-400 kb region of 6q24 which contains several CpG islands. At one island we have demonstrated differential DNA methylation between patients with paternal UPD of chromosome 6 and normal controls. In addition, two patients with TNDM, in whom neither paternal UPD of chromosome 6 nor duplication of 6q24 have been found, show a DNA methylation pattern identical to that of patients with paternal UPD of chromosome 6. Control individuals show a hemizygous methylation pattern. These results show that TNDM can be associated with a methylation change and identify a novel methylation imprint on chromosome 6 associated with TNDM.