Phase retrieval, or the process of recovering phase information in reciprocal space to reconstruct images from measured intensity alone, is the underlying basis to a variety of imaging applications ...including coherent diffraction imaging (CDI). Typical phase retrieval algorithms are iterative in nature, and hence, are time-consuming and computationally expensive, making real-time imaging a challenge. Furthermore, iterative phase retrieval algorithms struggle to converge to the correct solution especially in the presence of strong phase structures. In this work, we demonstrate the training and testing of CDI NN, a pair of deep deconvolutional networks trained to predict structure and phase in real space of a 2D object from its corresponding far-field diffraction intensities alone. Once trained, CDI NN can invert a diffraction pattern to an image within a few milliseconds of compute time on a standard desktop machine, opening the door to real-time imaging.
Trace metals play important roles in normal and in disease-causing biological functions. X-ray fluorescence microscopy reveals trace elements with no dependence on binding affinities (unlike with ...visible light fluorophores) and with improved sensitivity relative to electron probes. However, X-ray fluorescence is not very sensitive for showing the light elements that comprise the majority of cellular material. Here we show that X-ray ptychography can be combined with fluorescence to image both cellular structure and trace element distribution in frozen-hydrated cells at cryogenic temperatures, with high structural and chemical fidelity. Ptychographic reconstruction algorithms deliver phase and absorption contrast images at a resolution beyond that of the illuminating lens or beam size. Using 5.2-keV X-rays, we have obtained sub–30-nm resolution structural images and ∼90-nm–resolution fluorescence images of several elements in frozen-hydrated green algae. This combined approach offers a way to study the role of trace elements in their structural context.
Significance X-ray fluorescence microscopy provides unparalleled sensitivity for measuring the distribution of trace elements in many-micrometer-thick specimens, whereas ptychography offers a path to the imaging of weakly fluorescing biological ultrastructure at beyond-focusing-optic resolution. We demonstrate here for the first time, to our knowledge, the combination of fluorescence and ptychography for imaging frozen-hydrated specimens at cryogenic temperatures, with excellent structural and chemical preservation. This combined approach will have significant impact on studies of the intracellular localization of nanocomposites with attached therapeutic or diagnostic agents, help elucidate the roles of trace metals in cell development, and further the study of diseases where trace metal misregulation is suspected (including neurodegenerative diseases).
Coronary heart disease is a common cause of death despite being preventable. To treat the underlying plaque deposits in the arterial walls, intravascular optical coherence tomography can be used by ...experts to detect and characterize the lesions. In clinical routine, hundreds of images are acquired for each patient, which require automatic plaque detection for fast and accurate decision support. So far, automatic approaches rely on classic machine learning methods and deep learning solutions have rarely been studied. Given the success of deep learning methods with other imaging modalities, a thorough understanding of deep learning-based plaque detection for future clinical decision support systems is required. We address this issue with a new data set consisting of in vivo patient images labeled by three trained experts. Using this data set, we employ the state-of-the-art deep learning models that directly learn plaque classification from the images. For improved performance, we study different transfer learning approaches. Furthermore, we investigate the use of Cartesian and polar image representations and employ data augmentation techniques tailored to each representation. We fuse both representations in a multi-path architecture for more effective feature exploitation. Last, we address the challenge of plaque differentiation in addition to detection. Overall, we find that our combined model performs best with an accuracy of 91.7%, a sensitivity of 90.9%, and a specificity of 92.4%. Our results indicate that building a deep learning-based clinical decision support system for plaque detection is feasible.
Cobalt-Chromium (Co-Cr) alloys are classified as predominantly base-metal alloys and are widely known for their biomedical applications in the orthopedic and dental fields. In dentistry, Co-Cr alloys ...are commonly used for the fabrication of metallic frameworks of removable partial dentures and recently have been used as metallic substructures for the fabrication of porcelain-fused-to-metal restorations and implant frameworks. The increased worldwide interest in utilizing Co-Cr alloys for dental applications is related to their low cost and adequate physico-mechanical properties. Additionally, among base-metal alloys, Co-Cr alloys are used more frequently in many countries to replace Nickel-Chromium (Ni-Cr) alloys. This is mainly due to the increased concern regarding the toxic effects of Ni on the human body when alloys containing Ni are exposed to the oral cavity. This review article describes dental applications, metallurgical characterization, and physico-mechanical properties of Co-Cr alloys and also addresses their clinical and laboratory behavior in relation to those properties.
Atomic clocks are vital in a wide array of technologies and experiments, including tests of fundamental physics
. Clocks operating at optical frequencies have now demonstrated fractional stability ...and reproducibility at the 10
level, two orders of magnitude beyond their microwave predecessors
. Frequency ratio measurements between optical clocks are the basis for many of the applications that take advantage of this remarkable precision. However, the highest reported accuracy for frequency ratio measurements has remained largely unchanged for more than a decade
. Here we operate a network of optical clocks based on
Al
(ref.
),
Sr (ref.
) and
Yb (ref.
), and measure their frequency ratios with fractional uncertainties at or below 8 × 10
. Exploiting this precision, we derive improved constraints on the potential coupling of ultralight bosonic dark matter to standard model fields
. Our optical clock network utilizes not just optical fibre
, but also a 1.5-kilometre free-space link
. This advance in frequency ratio measurements lays the groundwork for future networks of mobile, airborne and remote optical clocks that will be used to test physical laws
, perform relativistic geodesy
and substantially improve international timekeeping
.
According to the WHO, the proportion of people over 60 years is increasing and expected to reach 22% of total world’s population in 2050. In parallel, recent animal demographic studies have shown ...that the life expectancy of pet dogs and cats is increasing. Brain aging is associated not only with molecular and morphological changes but also leads to different degrees of behavioral and cognitive dysfunction. Common age-related brain lesions in humans include brain atrophy, neuronal loss, amyloid plaques, cerebrovascular amyloid angiopathy, vascular mineralization, neurofibrillary tangles, meningeal osseous metaplasia, and accumulation of lipofuscin. In aging humans, the most common neurodegenerative disorder is Alzheimer’s disease (AD), which progressively impairs cognition, behavior, and quality of life. Pathologic changes comparable to the lesions of AD are described in several other animal species, although their clinical significance and effect on cognitive function are poorly documented. This review describes the commonly reported age-associated neurologic lesions in domestic and laboratory animals and the relationship of these lesions to cognitive dysfunction. Also described are the comparative interspecies similarities and differences to AD and other human neurodegenerative diseases including Parkinson’s disease and progressive supranuclear palsy, and the spontaneous and transgenic animal models of these diseases.
X-ray microscopy can be used to image whole, unsectioned cells in their native hydrated state. It complements the higher resolution of electron microscopy for submicrometer thick specimens, and the ...molecule-specific imaging capabilites of fluorescence light microscopy. We describe here the first use of fast, continuous x-ray scanning of frozen hydrated cells for simultaneous sub-20 nm resolution ptychographic transmission imaging with high contrast, and sub-100 nm resolution deconvolved x-ray fluorescence imaging of diffusible and bound ions at native concentrations, without the need to add specific labels. By working with cells that have been rapidly frozen without the use of chemical fixatives, and imaging them under cryogenic conditions, we are able to obtain images with well preserved structural and chemical composition, and sufficient stability against radiation damage to allow for multiple images to be obtained with no observable change.
Ptychography is a coherent diffraction imaging (CDI) method for extended objects in which diffraction patterns are acquired sequentially from overlapping coherent illumination spots. The object's ...complex transmission function can be reconstructed from those diffraction patterns at a spatial resolution limited only by the scattering strength of the object and the detector geometry. Most experiments to date have positioned the illumination spots on the sample using a move-settle-measure sequence in which the move and settle steps can take longer to complete than the measure step. We describe here the use of a continuous "fly-scan" mode for ptychographic data collection in which the sample is moved continuously, so that the experiment resembles one of integrating the diffraction patterns from multiple probe positions. This allows one to use multiple probe mode reconstruction methods to obtain an image of the object and also of the illumination function. We show in simulations, and in x-ray imaging experiments, some of the characteristics of fly-scan ptychography, including a factor of 25 reduction in the data acquisition time. This approach will become increasingly important as brighter x-ray sources are developed, such as diffraction limited storage rings.
Parallel ptychographic reconstruction Nashed, Youssef S G; Vine, David J; Peterka, Tom ...
Optics express,
12/2014, Volume:
22, Issue:
26
Journal Article
Peer reviewed
Open access
Ptychography is an imaging method whereby a coherent beam is scanned across an object, and an image is obtained by iterative phasing of the set of diffraction patterns. It is able to be used to image ...extended objects at a resolution limited by scattering strength of the object and detector geometry, rather than at an optics-imposed limit. As technical advances allow larger fields to be imaged, computational challenges arise for reconstructing the correspondingly larger data volumes, yet at the same time there is also a need to deliver reconstructed images immediately so that one can evaluate the next steps to take in an experiment. Here we present a parallel method for real-time ptychographic phase retrieval. It uses a hybrid parallel strategy to divide the computation between multiple graphics processing units (GPUs) and then employs novel techniques to merge sub-datasets into a single complex phase and amplitude image. Results are shown on a simulated specimen and a real dataset from an X-ray experiment conducted at a synchrotron light source.
Three Co-Cr alloy types (Co-Cr-Mo, Co-Cr-W, and Co-Cr-Mo-W) have been commonly used in the fabrication of dental prostheses. These alloys can be manufactured using either conventional casting or ...selective laser melting (SLM) techniques. Nevertheless, research that directly compares these materials and/or manufacturing processes in terms of their microstructural and mechanical characteristics is sparse.
The purpose of this in vitro study was to conduct microstructural and mechanical analysis via X-ray interpretation, optical microscopy, scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS), image analysis, X-ray diffraction (XRD), instrumented indentation testing (IIT), and 3-point bending testing to characterize Co-Cr-Mo, Co-Cr-W, and Co-Cr-Mo-W alloys produced through conventional casting and SLM.
Six Co-Cr-based alloys were analyzed and divided into 3 types based on their elemental composition (Co-Cr-Mo, Co-Cr-W, and Co-Cr-Mo-W). Additionally, each group was categorized based on the manufacturing process used (casting or SLM). X-ray scans were used to assess porosity. The microstructures of the specimens were assessed through SEM/EDS examination and XRD analysis. IIT was used to determine the Martens hardness (HM) and elastic index (ηIT), while the elastic modulus (E) was estimated through the 3-point bending test. The mechanical properties were statistically analyzed using 2-way analysis of variance (ANOVA) and the Tukey multiple comparison post hoc test, with alloy type and manufacturing process as discriminating variables (α=.05).
All cast groups exhibited gross porosity, while no pores or other flaws were found in the SLM groups. Based on the XRD results, the crystalline structure of all Co-Cr specimens consisted of the face-centered cubic γ phase (γ-fcc), along with the hexagonal close-packed ε phase (ε-hcp) and Cr23C6 carbide. Different microstructures were identified between the cast and SLM alloys. Significant differences were identified for the mean standard deviation HM (ranging from 2601 ±94 N/mm2 to 3633 ±61 N/mm2) and mean ±standard deviation ηIT (ranging from 16.8 ±0.3% to 20.9 ±0.3%) among alloys prepared by the same manufacturing process, while all SLM alloys had statistically higher HM and ηIT results than their cast counterparts (P<.05). No statistically significant differences were identified for the mean ±standard deviation Eb (ranging from 170 ±25 GPa to 244 ±36 GPa) among the groups prepared with the same manufacturing process (P>.05), but the SLM alloys had significantly higher results (P<.05) than the cast alloys.
In general, the manufacturing procedure significantly affected the porosity, microstructure, and mechanical properties of the tested Co–Cr alloys. SLM decreased the internal porosity, provided a uniform microstructure, and improved the mechanical properties for all the tested alloy types.