Objective The purpose of this study was to assess the impact of different positions on pelvic diameters by comparing pregnant and nonpregnant women who assumed a dorsal supine and kneeling squat ...position. Study Design In this cohort study from a tertiary referral center in Germany, we enrolled 50 pregnant women and 50 nonpregnant women. Pelvic measurements were obtained with obstetric magnetic resonance imaging pelvimetry with the use of a 1.5-T scanner. We compared measurements of the depth (anteroposterior (AP) and width (transverse diameters) of the pelvis between the 2 positions. Results The most striking finding was a significant 0.9-1.9 cm increase (7-15%) in the average transverse diameters in the kneeling squat position in both pregnant and nonpregnant groups. The average bispinous diameter in the pregnant group increased from 12.6 cm ± 0.65 cm in the supine dorsal to 14.5 cm ± 0.64 cm ( P < .0001) in the kneeling squat; in the nonpregnant group the increase was from 12 cm ± 0.76 cm to 13.9 cm ± 1.04 cm ( P < .0001). The average bituberous diameter in the pregnant group increased from 13.6 cm ± 0.93 cm in the supine dorsal to 14.5 cm ± 0.83 cm ( P < .0001) in the kneeling squat position; in the nonpregnant women the increase was from 12.6 cm ± 0.92 cm to 13.5 cm ± 0.88 cm ( P < .0001). Conclusion A kneeling squat position significantly increases the bony transverse and anteroposterior dimension in the mid pelvic plane and the pelvic outlet. Because this indicates that pelvic diameters change when women change positions, the potential for facilitation of delivery of the fetal head suggests further research that will compare maternal delivery positions is warranted.
Systemic treatment with sorafenib has been the standard of care (SOC) in patients with advanced Barcelona Clinic Liver Cancer (BCLC) stage C hepatocellular carcinoma (HCC) for more than a decade. ...TACE has been reported to allow better local tumor control in selected patients with BCLC stage C HCC.
A retrospective analysis of patients with BCLC stage C HCC that were treated with sorafenib and TACE was conducted; they were compared to BCLC stage C patients treated either with TACE or sorafenib in the same period of time outside a clinical trial.
A total of 201 patients with BCLC stage C were identified, who were treated with either sorafenib and TACE (group A;
= 54), sorafenib (group B;
= 82) or TACE (group C;
= 65). No significant difference in baseline characteristics was observed. Time to progression was 7.0 months (95% CI: 4.3-9.7), 4.1 months (95% CI: 3.6-4.7) and 5.0 months (95% CI: 2.9-7.1) in groups A, B and C, respectively, and overall survival was 16.5 months (95% CI: 15.0-18.1), 8.4 months (95% CI: 6.0-10.8) and 10.5 months (95% CI: 7.5-13.6), respectively (group A vs. group B:
< 0.001; group A vs. group C:
= 0.0023). Adverse events of grade 3/4 occurred in 34% of patients in group A.
Although sorafenib is a SOC in patients with BCLC stage C HCC, TACE is frequently used as an additional locoregional treatment in selected patients. This combined approach resulted in a significant overall survival benefit in selected patients, although randomized trials have not yet proven this benefit.
Objective
To analyse the feasibility and accuracy of robotic aided interventions on a phantom when using a modern C-arm-mounted cone beam computed tomography (CBCT) device in combination with needle ...guidance software.
Methods
A small robotic device capable of holding and guiding needles was attached to the intervention table. After acquiring a 3D data set the access path was planned on the CBCT workstation and shown on the intervention monitor. Then the robot was aligned to the live fluorosopic image. A total of 40 punctures were randomly conducted on a phantom armed with several targets (diameter 2 mm) in single and double oblique trajectory (
n
= 20 each). Target distance, needle deviation and time for the procedures were analysed.
Results
All phantom interventions (
n
= 40) could be performed successfully. Mean target access path within the phantom was 8.5 cm (min 4.2 cm, max 13.5 cm). Average needle tip deviation was 1.1 mm (min 0 mm, max 4.5 mm), time duration was 3:59 min (min 2:07 min, max 10:37 min).
Conclusion
When using the proposed robot device in a CBCT intervention suite, highly accurate needle-based interventional punctures are possible in a reasonable timely manner in single as well as in double oblique trajectories.
Key Points
•
Percutaneous image-guided biopsy is an important contribution of modern radiology.
•
A compact robotic device has been developed which may facilitate such procedures.
•
Accurate needle-based interventions are possible in a timely manner.
•
Complex trajectories and even deep access paths are possible.
Liver metastasis is one of the main problems encountered in colorectal cancer management as the liver is the most common metastatic site. Several treatment options are available, among which ...transarterial chemotherapy has proved effective in achieving some local tumour control, improving the quality of life through symptomatic control as well as survival time. The present paper is intended to provide an overview of the techniques, indications and results of regional chemotherapy, which comprises transarterial chemoembolization (TACE) and chemoperfusion. This treatment approach has symptomatic, palliative, adjuvant and potentially curative objectives. We reviewed the studies involving TACE and chemoperfusion of colorectal liver metastases during the last few years to update the previous reviews published on this subject. The results achieved were so variable, due to the variations in patient selection criteria and regimens used between the different studies. The median survival ranged from 9 to 62 months and the morphological response ranged from 14 to 76%. Technical aspects, results, and complications of this modality will be demonstrated with a detailed analysis and comments.
The aim of this study was to evaluate treatment of osteoid osteomas using bipolar radiofrequency ablation (RFA) and patients' quality of life before and after therapy. We retrospectively evaluated ...patients who underwent bipolar RFA of osteoid osteomas between 2001 and 2016. We assessed patients' symptoms before and after treatment (four weeks after treatment and long-term) using a questionnaire including severity and quality of pain on a 10-point scale (1 = no pain, 10 = severe pain), motion restrictions, pain-related sleep disorders, and necessary pain medication. In addition, we evaluated technical success, complications, hospitalization length, and patients' satisfaction with treatment. This study included 62 patients (43 69.4% males, 26.2 ± 13.2 years). Average nidus size was 5.7 ± 2.6 mm. The rate of technical success was 100%. All RFAs were performed without any complications. One patient showed a recurrence, resulting in a recurrence rate of 1.6%, which was successfully treated by another session of RFA. Average hospitalization length was 1.5 ± 0.5 days. A total of 36 patients (58.1%) participated in the questionnaire, reporting an average pain severity of 8.2 ± 1.6 before RFA compared to 3.4 ± 3.0 four weeks after and an average of 2.1 ± 2.3, 6.6 years after therapy, (both
< 0.001). After therapy, 31 (86.1%) patients had no pain. The majority of patients (
= 34, 94.4%) had reduced or absent motion restriction after therapy (
< 0.001). Patient satisfaction rate was 91.7%. In conclusion, bipolar RFA is a safe and effective treatment modality for osteoid osteomas and improves quality of life by reducing pain severity and motion restrictions.
: The uterus is composed of different smooth muscle layers that serve various functions. First, menstrual debris is expulsed at the time of the menses. Second, sperm is transported in the ...preovulatory phase to maximize fertility, and third, the human embryo is placed in an adequate setting during implantation. Endometriosis is a gynecologic disorder leading to severe pain symptoms such as severe pain during menstruation (dysmenorrhea), chronic pelvic pain, pain during sexual intercourse (dyspareunia), and abnormal uterine bleeding. Besides, endometriosis is often associated with female infertility and exhibits a massive impairment in the physiology of uterine contractility that can be documented by the in vivo examination method of hysterosalpingoscintigraphy (HSSG). In addition, endometriosis is associated in 80–90% of subjects with adenomyosis and our data clearly indicate that sperm transport is disturbed by hyperperistalsis when at least one focus of adenomyosis can be detected via magnetic resonance imaging (MRI) and turns into dysperistalsis (a complete failure in sperm transport capacity) when diffuse adenomyosis affecting all myometrial uterine muscle layers is detected. Hence, dysperistalsis is significantly associated with reduced spontaneous pregnancy rates. We therefore recommend MRI and HSSG in every sterility workup.
To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography ...scans (CTA) or a specifically designed phantom model.
This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
•Pre-interventional planning of TEVAR in patients with TAAs using CTA is feasible.•All three workstations facilitated accurate measurements in vivo and ex vivo.•Repetition of measurements resulted in faster processing due to learning effects.
This study was carried out to investigate the impact of abdominal dynamic four-dimensional CT angiography (4D-CTA) for guiding transarterial chemoembolization (TACE) on the amount of contrast ...material used, operator radiation exposure, catheter consumption, and diagnostic confidence.
Written consent was waived for this IRB-approved retrospective study. 29 patients (20 men; mean age: 65.7 ± 11.5 years) with malignant liver lesions underwent 4D-CTA, prior to initial TACE. Time-resolved volume-rendering technique (VRT), maximum-intensity projection (MIP), and multiplanar reconstruction (MPR) series were reconstructed, enabling a direct selective catheterization of the tumor-supplying artery without prior conventional digital subtraction angiography (DSA). 29 patients (16 men; mean age: 69.4 ± 13.9) who underwent traditional TACE served as the control group. The amount of administered contrast media, operator radiation exposure, and catheter consumption during TACE were compared. Two radiologists assessed diagnostic confidence in the exclusion of portal vein thrombosis.
4D-CTA TACE resulted in a significant reduction in the amount of contrast media used, compared to traditional TACE (-61.0 ml/ -66.3 % intra-arterial, -12.8 ml/ -13.8 % overall; P < 0.001). The dose-area product indicating operator radiation exposure during intervention was reduced by 50.5 % (P < 0.001), and 0.7 fewer catheters on average were used (P = 0.063), while 4D-CTA data was available to guide TACE. Diagnostic confidence in the exclusion of portal vein thrombosis was significantly enhanced by 4D-CTA, compared to traditional DSA images (scores, 3.9 and 2.4, respectively; P < 0.001).
Dynamic 4D-CTA enables TACE with a substantially reduced amount of contrast material, decreases operator radiation exposure, and increases diagnostic confidence in the exclusion of portal vein thrombosis.
· 4D-CTA prior to TACE decreases the amount of utilized contrast material.. · The intra-arterial fraction of contrast media can be reduced by two-thirds.. · The risk of CIN may be decreased by means of 4D-CTA TACE.. · Operator radiation exposure is lower using 4D-CTA for guiding TACE.. · 4D-CTA portography allows for a higher diagnostic confidence than conventional DSA images..
· Albrecht MH, Vogl TJ, Wichmann JL et al. Dynamic 4D-CT Angiography for Guiding Transarterial Chemoembolization: Impact on the Reduction of Contrast Material, Operator Radiation Exposure, Catheter Consumption, and Diagnostic Confidence. Fortschr Röntgenstr 2018; 190: 513 - 520.