Mammography is not widely available in all countries, and breast cancer incidence is increasing. We considered performance characteristics using ultrasound (US) instead of mammography to screen for ...breast cancer.
Two thousand eight hundred nine participants were enrolled at 20 sites in the United States, Canada, and Argentina in American College of Radiology Imaging 6666. Two thousand six hundred sixty-two participants completed three annual screens (7473 examinations) with US and film-screen (n = 4351) or digital (n = 3122) mammography and had biopsy or 12-month follow-up. Cancer detection, recall, and positive predictive values were determined. All statistical tests were two-sided.
One hundred ten women had 111 breast cancer events: 89 (80.2%) invasive cancers, median size 12 mm. The number of US screens to detect one cancer was 129 (95% bootstrap confidence interval CI = 110 to 156), and for mammography 127 (95% CI = 109 to 152). Cancer detection was comparable for each of US and mammography at 58 of 111 (52.3%) vs 59 of 111 (53.2%, P = .90), with US-detected cancers more likely invasive (53/58, 91.4%, median size 12 mm, range = 2-40 mm), vs mammography at 41 of 59 (69.5%, median size 13 mm, range = 1-55 mm, P < .001). Invasive cancers detected by US were more frequently node-negative, 34 of 53 (64.2%) vs 18 of 41 (43.9%) by mammography (P = .003). For 4814 incidence screens (years 2 and 3), US had higher recall and biopsy rates and lower PPV of biopsy (PPV3) than mammography: The recall rate was 10.7% (n = 515) vs 9.4% (n = 453, P = .03), the biopsy rate was 5.5% (n = 266) vs 2.0% (n = 97, P < .001), and PPV3 was 11.7% (31/266) vs 38.1% (37/97, P < .001).
Cancer detection rate with US is comparable with mammography, with a greater proportion of invasive and node-negative cancers among US detections. False positives are more common with US screening.
Ultrasonography (US) is an indispensable tool in breast imaging and is complementary to both mammography and magnetic resonance (MR) imaging of the breast. Advances in US technology allow confident ...characterization of not only benign cysts but also benign and malignant solid masses. Knowledge and understanding of current and emerging US technology, along with the application of meticulous scanning technique, is imperative for image optimization and diagnosis. The ability to synthesize breast US findings with multiple imaging modalities and clinical information is also necessary to ensure the best patient care. US is routinely used to guide breast biopsies and is also emerging as a supplemental screening tool in women with dense breasts and a negative mammogram. This review provides a summary of current state-of-the-art US technology, including elastography, and applications of US in clinical practice as an adjuvant technique to mammography, MR imaging, and the clinical breast examination. The use of breast US for screening, preoperative staging for breast cancer, and breast intervention will also be discussed.
The detection of regional lymph node metastases is important in cancer staging as it guides the prognosis of the patient and the strategy for treatment. Sentinel lymph node biopsy (SLNB) is an ...accurate, less invasive alternative to axillary lymph node dissection. The sentinel lymph node hypothesis states that the pathological status of the axilla can be accurately predicted by determining the status of the first lymph nodes that drain from the primary tumor. Physicians use radio-labeled sulfur colloid and/or methylene blue dye to identify the SLN, which is most likely to contain metastatic cancer cells. However, the surgical procedure causes morbidity and associated expenses. To overcome these limitations, we developed a dual-modality photoacoustic and ultrasonic imaging system to noninvasively detect SLNs based on the accumulation of methylene blue dye. Ultimately, we aim to guide percutaneous needle biopsies and provide a minimally invasive method for axillary staging of breast cancer.
Fast and accurate tissue elasticity imaging is essential in studying dynamic tissue mechanical properties. Various ultrasound shear elasticity imaging techniques have been developed in the last two ...decades. However, to reconstruct a full field-of-view 2-D shear elasticity map, multiple data acquisitions are typically required. In this paper, a novel shear elasticity imaging technique, comb-push ultrasound shear elastography (CUSE), is introduced in which only one rapid data acquisition (less than 35 ms) is needed to reconstruct a full field-of-view 2-D shear wave speed map (40 × 38 mm). Multiple unfocused ultrasound beams arranged in a comb pattern (comb-push) are used to generate shear waves. A directional filter is then applied upon the shear wave field to extract the left-to-right (LR) and right-to-left (RL) propagating shear waves. Local shear wave speed is recovered using a time-of-flight method based on both LR and RL waves. Finally, a 2-D shear wave speed map is reconstructed by combining the LR and RL speed maps. Smooth and accurate shear wave speed maps are reconstructed using the proposed CUSE method in two calibrated homogeneous phantoms with different moduli. Inclusion phantom experiments demonstrate that CUSE is capable of providing good contrast (contrast-to-noise ratio ≥25 dB) between the inclusion and background without artifacts and is insensitive to inclusion positions. Safety measurements demonstrate that all regulated parameters of the ultrasound output level used in CUSE sequence are well below the FDA limits for diagnostic ultrasound.
Application of the frequency domain acoustic wave equation on data acquired from ultrasound tomography scans is shown to yield high resolution sound speed images on the order of the wavelength of the ...highest reconstructed frequency. Using a signal bandwidth of 0.4-1 MHz and an average sound speed of 1500 m s(-1), the resolution is approximately 1.5 mm. The quantitative sound speed values and morphology provided by these images have the potential to inform diagnosis and classification of breast disease. In this study, we present the formalism, practical application, and in vivo results of waveform tomography applied to breast data gathered by two different ultrasound tomography scanners that utilize ring transducers. The formalism includes a review of frequency domain modeling of the wave equation using finite difference operators as well as a review of the gradient descent method for the iterative reconstruction scheme. It is shown that the practical application of waveform tomography requires an accurate starting model, careful data processing, and a method to gradually incorporate higher frequency information into the sound speed reconstruction. Following these steps resulted in high resolution quantitative sound speed images of the breast. These images show marked improvement relative to commonly used ray tomography reconstruction methods. The robustness of the method is demonstrated by obtaining similar results from two different ultrasound tomography devices. We also compare our method to MRI to demonstrate concordant findings. The clinical data used in this work was obtained from a HIPAA compliant clinical study (IRB 040912M1F).
In 2009, the U.S. Preventive Services Task Force recommended biennial mammography screening for women aged 50 to 74 years and selective screening for those aged 40 to 49 years.
To review studies of ...screening in average-risk women with mammography, magnetic resonance imaging, or ultrasonography that reported on false-positive results, overdiagnosis, anxiety, pain, and radiation exposure.
MEDLINE and Cochrane databases through December 2014.
English-language systematic reviews, randomized trials, and observational studies of screening.
Investigators extracted and confirmed data from studies and dual-rated study quality. Discrepancies were resolved through consensus.
Based on 2 studies of U.S. data, 10-year cumulative rates of false-positive mammography results and biopsies were higher with annual than biennial screening (61% vs. 42% and 7% vs. 5%, respectively) and for women aged 40 to 49 years, those with dense breasts, and those using combination hormone therapy. Twenty-nine studies using different methods reported overdiagnosis rates of 0% to 54%; rates from randomized trials were 11% to 22%. Women with false-positive results reported more anxiety, distress, and breast cancer-specific worry, although results varied across 80 observational studies. Thirty-nine observational studies indicated that some women reported pain during mammography (1% to 77%); of these, 11% to 46% declined future screening. Models estimated 2 to 11 screening-related deaths from radiation-induced cancer per 100,000 women using digital mammography, depending on age and screening interval. Five observational studies of tomosynthesis and mammography indicated increased biopsies but reduced recalls compared with mammography alone.
Studies of overdiagnosis were highly heterogeneous, and estimates varied depending on the analytic approach. Studies of anxiety and pain used different outcome measures. Radiation exposure was based on models.
False-positive results are common and are higher for annual screening, younger women, and women with dense breasts. Although overdiagnosis, anxiety, pain, and radiation exposure may cause harm, their effects on individual women are difficult to estimate and vary widely.
Agency for Healthcare Research and Quality.
Computer-aided diagnosis (CAD) has been a popular area of research and development in the past few decades. In CAD, machine learning methods and multidisciplinary knowledge and techniques are used to ...analyze the patient information and the results can be used to assist clinicians in their decision making process. CAD may analyze imaging information alone or in combination with other clinical data. It may provide the analyzed information directly to the clinician or correlate the analyzed results with the likelihood of certain diseases based on statistical modeling of the past cases in the population. CAD systems can be developed to provide decision support for many applications in the patient care processes, such as lesion detection, characterization, cancer staging, treatment planning and response assessment, recurrence and prognosis prediction. The new state-of-the-art machine learning technique, known as deep learning (DL), has revolutionized speech and text recognition as well as computer vision. The potential of major breakthrough by DL in medical image analysis and other CAD applications for patient care has brought about unprecedented excitement of applying CAD, or artificial intelligence (AI), to medicine in general and to radiology in particular. In this paper, we will provide an overview of the recent developments of CAD using DL in breast imaging and discuss some challenges and practical issues that may impact the advancement of artificial intelligence and its integration into clinical workflow.
To determine performance and utilization of screening breast ultrasonography (US) in women with dense breast tissue who underwent additional screening breast US in the 1st year since implementation ...of Connecticut Public Act 09-41 requiring radiologists to inform patients with heterogeneous or extremely dense breasts at mammography that they may benefit from such examination.
Informed consent was waived for this institutional review board-approved, HIPAA-compliant retrospective review of 935 women with dense breasts at mammography who subsequently underwent handheld screening and whole-breast US from October 1, 2009, through September 30, 2010.
Of 935 women, 614 (65.7%) were at low risk, 149 (15.9%) were at intermediate risk, and 87 (9.3%) were at high risk for breast cancer. Of the screening breast US examinations, in 701 (75.0%), results were classified as Breast Imaging Reporting and Data System (BI-RADS) category 1 or 2; in 187 (20.0%), results were classified as BI-RADS category 3; and in 47 (5.0%), results were classified as BI-RADS category 4. Of 63 aspirations or biopsies recommended and performed in 53 patients, in nine, lesions were BI-RADS category 3, and in 54, lesions were BI-RADS category 4. Among 63 biopsies and aspirations, three lesions were malignant (all BI-RADS category 4, diagnosed with biopsy). All three cancers were smaller than 1 cm, were found in postmenopausal patients, and were solid masses. One cancer was found in each risk group. In 44 of 935 (4.7%) patients, examination results were false-positive. Overall positive predictive value (PPV) for biopsy or aspirations performed in patients with BI-RADS category 4 masses was 6.5% (three of 46; 95% confidence interval CI: 1.7%, 19%). Overall cancer detection rate was 3.2 cancers per 1000 women screened (three of 935; 95% CI: 0.8 cancers per 1000 women screened, 10 cancers per 1000 women screened).
Technologist-performed handheld screening breast US offered to women in the general population with dense breasts can aid detection of small mammographically occult breast cancers (cancer detection rate, 0.8-10 cancers per 1000 women screened), although the overall PPV is low.
Abstract
The technical part of these Guidelines and Recommendations, produced under the auspices of EFSUMB, provides an introduction to the physical principles and technology on which all forms of ...current commercially available ultrasound elastography are based. A difference in shear modulus is the common underlying physical mechanism that provides tissue contrast in all elastograms. The relationship between the alternative technologies is considered in terms of the method used to take advantage of this. The practical advantages and disadvantages associated with each of the techniques are described, and guidance is provided on optimisation of scanning technique, image display, image interpretation and some of the known image artefacts.
Many states have laws requiring mammography facilities to tell women with dense breasts and negative results on screening mammography to discuss supplemental screening tests with their providers. The ...most readily available supplemental screening method is ultrasonography, but little is known about its effectiveness.
To evaluate the benefits, harms, and cost-effectiveness of supplemental ultrasonography screening for women with dense breasts.
Comparative modeling with 3 validated simulation models.
Surveillance, Epidemiology, and End Results Program; Breast Cancer Surveillance Consortium; and medical literature.
Contemporary cohort of women eligible for routine screening.
Lifetime.
Payer.
Supplemental ultrasonography screening for women with dense breasts after a negative screening mammography result.
Breast cancer deaths averted, quality-adjusted life-years (QALYs) gained, biopsies recommended after a false-positive ultrasonography result, and costs.
Supplemental ultrasonography screening after a negative mammography result for women aged 50 to 74 years with heterogeneously or extremely dense breasts averted 0.36 additional breast cancer deaths (range across models, 0.14 to 0.75), gained 1.7 QALYs (range, 0.9 to 4.7), and resulted in 354 biopsy recommendations after a false-positive ultrasonography result (range, 345 to 421) per 1000 women with dense breasts compared with biennial screening by mammography alone. The cost-effectiveness ratio was $325,000 per QALY gained (range, $112,000 to $766,000). Supplemental ultrasonography screening for only women with extremely dense breasts cost $246,000 per QALY gained (range, $74,000 to $535,000).
The conclusions were not sensitive to ultrasonography performance characteristics, screening frequency, or starting age.
Provider costs for coordinating supplemental ultrasonography were not considered.
Supplemental ultrasonography screening for women with dense breasts would substantially increase costs while producing relatively small benefits.