A novel technique of digitally printed custom trays assembled with occlusion rims and gothic arch tracing devices attached with tenon-and-mortise joints for biofunctional complete dentures that could ...be delivered in 2 visits is presented. This technique takes advantage of closed-mouth impressions and objective jaw relation records by following the biofunctional prosthetic system concept with high efficiency and reduced labor.
Ectodermal Dysplasia (ED) is a rare congenital syndrome that exhibits defects in two or more ectodermal tissues. Dental manifestations include delayed eruption of permanent dentition, complete ...absence of teeth or absence of a few teeth, and peg-shaped teeth. This condition is typically diagnosed by a dentist when parents bring their child with complaints of absent/delayed eruption of primary teeth. Hypohidrotic ED with true anodontia is an extremely rare condition, particularly in females. Over the past 50 years, only 11 cases have been reported involving anodontia of primary and permanent dentition in ED. The current report describes a case of a three-year-old female child diagnosed with hypohidrotic ED with anodontia, successfully treated by fabricating complete dentures with proper retention to restore function and aesthetics.
This study evaluated the reliability of a face scanner in measuring the vertical dimension of occlusion (VDO).
Fully dentate volunteers (n = 20; mean-age = 30.0 ± 10.7 years) were recruited. Clinical ...facial measurements were obtained using a digital caliper and a face scanner (Obiscanner, Fifthingenium, Italy). The scans were imported into a mesh-processing software, and the distances were measured digitally. Measurements were obtained for each participant with the jaws positioned in maximal intercuspation (MI) and with increased vertical distances of 2, 4, and 6 mm. Vertical and horizontal measures were obtained using facial anatomical landmarks: Glabella (GL), Pronasale (PrN), Subnasale (SbN), inferior border of the right and left Alare, Labiale superius (Ls), right and left Cheilion (Ch), Soft Pogonion (SPg), right and left Tragus of the ear (Tr), for all selected vertical positions. Data analysis included intra-class correlation coefficient (ICC), pairwise comparison tests, Bland-Altman plots, and Passing-Bablok regression.
120 VDO measurements (clinical=60, digital=60) were recorded by two independent evaluators. Mean differences between digital and clinical measurements ranged from 0.054 ± 0.14 mm to 0.203 ± 0.13 mm. All parameters were strongly correlated (r > 0.93; p < 0.001). ICC estimates revealed excellent reliability, and the measuring procedure yielded the same results on repeated trials irrespective of the raters and measurement methods. Bland-Altman plots revealed a difference, between digital and clinical measurements, of 1.7 % for the vertical measurements. Regression analysis revealed no significant proportional difference between the two methods, so both can be used interchangeably.
The findings of this study demonstrate that VDO can be measured accurately from face scans using 3D mesh-processing software and that even small changes in the VDO could be detected using the digital methods.
Findings provide evidence about the reliability of a digital method for jaw relation registrations and may be applied towards incorporating this method into clinical workflows for computer-aided-design/ computer-assisted-manufacturing (CAD-CAM) dentures.
Introduction. Many alternatives exist for treating total edentulism, including conventional complete dentures (CCD), implant-supported overdentures, and implant-supported fixed prostheses. Complete ...dentures have been the standard prosthodontic therapy for people who are edentulous for quite some time. The majority of denture-wearing edentulous patients are pleased with their prostheses, but some people just can’t get used to them, and it seems that the level of clinical and technical expertise involved or the quality of the tissues supporting the dentures have little effect on how happy those people are with their results. While the routine prescription of an overdenture supported by two or even one implant for an edentulous mandible is becoming the standard of care in many developed nations, this treatment option is out of reach for the majority of the world’s poor, who often cannot afford even “low-tech” therapies like conventional dentures.
AIMTo compare and evaluate the mean bite force and masticatory performance of conventional complete dentures (CD) in comparison with the lower implant-supported overdenture opposing an upper CD by ...using a strain gauge transducer and a test material respectively, in the same patient over a different period of time. MATERIALS AND METHODSThe study included 20 edentulous patients in the age range 45-65 years with a good general and oral health. In the first phase of the study, conventional CD were fabricated and delivered to each patient who participated in the study. A strain gauge transducer was used to analyze the maximum bite force and an agar test material was used to assess the masticatory performance using the sieve method. The existing lower denture was used to deliver a two-implant overdenture system and two implants were placed in the intermental-foraminal region of the mandible. One month after the delivery of implant-supported overdenture, the maximum bite force and masticatory performance were assessed as before. RESULTSTo test two independent variables, the data were analyzed statistically using an unpaired t-test. In comparison to the conventional upper and lower CD rehabilitations, the implant-supported lower denture and conventional upper CD rehabilitations resulted in statistically significant improvements in biting force and masticatory performance. CONCLUSIONStudy findings demonstrate that the completely edentulous patients can be rehabilitated with the upper CD and lower two-implant supported overdenture system that offers improved biting force and masticatory performance than conventional upper and lower dentures. CLINICAL SIGNIFICANCEMasticatory efficiency is one of the important indicators of functional state of stomatognathic system. Determination of individual masticatory performance has been used to ascertain the therapeutic effect of prosthetic device.
This review compared Computer-aided designand Computer-aided manufactured (CAD-CAM) and conventionally constructed removable complete dentures (CDs).
Seventy-three studies reporting on CAD-CAM ...(milled/3D-printed) CDs were included in this review. The most recent literature search was performed on 15/03/2021.
Two investigators searched electronic databases PubMed (MEDLINE), Embase, CENTRAL, online search engines (Google) and research portals. Hand searches were performed to identify literature not available online.
Studies on CAD-CAM CDs were included if they reported on trueness of fit, biocompatibility, mechanical, surface, chemical, color , microbiological properties, time-cost analysis, and clinical outcomes. Inter-investigator reliability was assessed using kappa scores. Meta-analyses were performed on the extracted data .
The kappa score ranged between 0.897–1.000. Meta-analyses revealed that 3D-printed CDs were more true than conventional CDs (p = 0.039). Milled CDs had a higher flexural-strength than conventional and 3D-printed CDs (p < 0.0001). Milled CDs had a higher flexural-modulus than 3D-printed CDs (p < 0.0001). Milled CDs had a higher yield-strength than injection-molded (p = 0.004), and 3D-printed CDs (p = 0.001). Milled CDs had superior toughness (p < 0.0001) and surface roughness characteristics (p < 0.0001) than other CDs . Rapidly-prototyped CDs displayed poor color-stability compared to other CDs (p = 0.029). CAD-CAM CDs d displayed better retention than conventional CDs (p = 0.015). Conventional CDs had a higher strain at yield point than milled CDs (p < 0.0001), and had superior esthetics than 3D-printed (p < 0.0001). Fabrication of CAD-CAM CDs required less chairside time (p = 0.037) and lower overall costs (p < 0.0001) than conventional CDs.
This systematic review concludes that CAD-CAM CDs offer a number of improved mechanical/surface properties and are not inferior when compared to conventional CDs.
CAD-CAM CDs should be considered for completely edentulous patients whenever possible, since this technique offers numerous advantages including better retention, mechanical and surface properties but most importantly preserves a digital record. This can be a great advantage for older adults with limited access to dental care.
Background: The scientific interest in dominant Candida species colonizing the surface of conventional and double-layer dentures (D-LCDs) is still topical. Numerous studies are comparing fungal ...colonization in both types of removable dentures. Aim: Performing a comparative analysis of the colonization of Candida spp. on the dentures surfaces of the conventional (CCDs) and the double-layer dentures (soft-lined) complete dentures (D-LCDs) over six months, placing them under the same intraoral in vivo conditions. Methods: For isolating Candida spp., specimens were obtained from inner denture surfaces using two sterile swabs, one for the upper complete denture (n=28) and one for the lower complete denture (n=28). The culture-based Candida detection method with CHROM agar was used to identify Candida species. Results: In the third month after dentures delivery C. Albicans is the predominant Candida spp. found on both types of complete dentures surface and isolated in 46 % of the patients with conventional complete dentures and 43 % with double-layer dentures (p>0.05). In the sixth month of the finished prosthetic treatment, combinations of C. Albicans and non-albicans Candida, predominantly C. Tropicalis, C. Glabrata and C. Parapsilosis, were found in 43 % of D-LCDs and 45 % of CCDs (p>0.05). Conclusion: There was no difference in colonization based on the different materials used for denture fabrication. However, there is a significant proportional change for all studied Candida spp. over the period (3-6 months after delivery), irrespective of the denture material used.