Provider: - Institution: University of Zagreb. Faculty of Metallurgy. - Data provided by Europeana Collections- U ovom doktorskom radu provedena su usporedna istraživanja na čeliku mikrolegiranom ...niobijem koji ima sitne precipitate niobija, čeliku istog baznog kemijskog sastava bez dodatka niobija i niobijem mikrolegiranom čeliku s krupnim precipitatima niobija. Uz statički vlačni pokus istovremeno su primijenjene metode termografije i digitalne korelacije slike, koje omogućuju konstantno mjerenje promjena temperature i deformacije.
Primjenom programskih paketa IRBIS3 Professional i MatchID 2D omogućena je kvalitativna i kvantitativna analiza rezultata mjerenja promjena temperature i pomaka tijekom deformacije. Provedena istraživanja su pokazala da se čelik mikrolegiran niobijem značajno različito ponaša pri deformaciji u odnosu na čelik istog baznog sastava bez niobija. Utjecaj sitnih niobijevih precipitata naročito je izražen na početku plastičnog toka materijala. Nakon granice proporcionalnosti, niobijem mikrolegirani čelik ima reološki kompleksno ponašanje. Istraživanja su pokazala da je to ponašanje povezano s pojavom Lüdersovih linija. Lüdersova linija se formira na način da plastična deformacija započinje na jednom kraju uzorka, pri čemu se ostvari deformacija od 0,004 mm/mm. Nakon toga, Lüdersova linija propagira pod kutom od 45. Utvrđeno je da na fronti Lüdersove linije dolazi do porasta temperature od 4,5 do 6C, što je povezano s porastom naprezanja. Iza fronte linije ostvaruje se Lüdersova deformacija od 0,05 mm/mm. Nakon toga, u formiranoj zoni deformacije nastavlja se daljnja plastična deformacija, a naprezanja se koncentriraju u sredini zone deformacije, kao kod niskougljičnog čelika.
Predložen je matematički model koji povezuje naprezanja i deformaciju s izmjerenim promjenama temperatura, s kojim je moguće iz izmjerenih vrijednosti deformacije i temperature odrediti iznose naprezanja u promatranim točkama. Usporedbom rezultata istraživanja i rezultata dobivenih razvijenim modelom, pokazalo se kako se vrijednosti podudaraju sve do brzine 30 mm/min, gdje su zabilježena značajna odstupanja.- In this doctoral thesis a comparative research were conducted on niobium microalloyed steel which has fine niobium precipitates, steel with same base chemical composition but without the addition of niobium and on niobium microalloyed steel with large precipitates of niobium.
With the tensile testing, at the same time the methods of thermography and digital image correlation were applied, which enables the continuous measurement of temperature changes and strain.
By using software packages IRBIS 3 Professional and MatchID 2D is enabled a quantitative and qualitative analysis of measured changes in temperature and strain. Research results have shown that microalloyed niobium steel has a significantly different behavior upon deformation in relation to the steel of the same base composition without niobium. Effect of the fine precipitates of niobium is especially pronounced at the beginning of plastic flow of material. After yielding the niobium microalloyed steel has rheological complex behavior. Research has shown that this behavior is associated with the occurrence of Lüders bands. Lüders band is formed in such way that plastic deformation starts at the one end of sample, in doing so the strain of 0,004 mm/mm is carried out. After that Lüders band propagates at the angle of 45°. It was found that on the Lüders band front there is increase in temperature of about 4.5 to 6 °C, which is associated with increases in stress. Behind the Lüders front the strain of 0.05 mm/mm is achieved, Lüders deformation. After that, in the formed deformation zone, further plastic deformation continues and stresses are concentrated in the centre of the deformation zone, as in the low-carbon steel.
Proposed mathematical model links measured stress and deformation with the measured temperature changes, with which is possible from the measured values of deformation and temperature changes determine the amount of stress in the observed points of deformation zone. By comparing the results of the research and the results obtained by the developed model, it was shown that the values match up to the speed of 30 mm / min, where is shown a significant discrepancies.- All metadata published by Europeana are available free of restriction under the Creative Commons CC0 1.0 Universal Public Domain Dedication. However, Europeana requests that you actively acknowledge and give attribution to all metadata sources including Europeana
Infracrvena termografija je siguran i neinvazivan način provjere fizioloških funkcija, baziran na kontroli temperature kože. Cilj ovog rada bio je utvrditi moguće toplinske razlike između vrijednosti ...zabilježenih na početku i na kraju rehabilitacijskog procesa nakon operacije prednjih križnih ligamenata. Iz tog su razloga napravljeni termogrami na 25 operiranih ispitanika (2 žene, 23 muškarca). Razmak između mjerenja bio je šest tjedana, a ispitanici su mjereni FLIR infracracrvenom kamerom prema protokolu International Academy of Clinical Thermology (IACT). Rezultati su pokazali značajno povećanje temperature u području stražnje strane natkoljenice između prvoga i posljednjega tjedna rehabilitacije, vjerojatno zbog pojave kompenzacije u mišićnoj aktivnosti. Može se zaključiti da se temperatura stražnje strane natkoljenice ozlijeđene, ali i zdrave noge značajno povećala između prvog i šestog tjedna rehabilitacijskog procesa.
Provider: - Institution: University of Zagreb. School of Dental Medicine. Department of Endodontics and Restorative Dentistry. - Data provided by Europeana Collections- Svrha je istraživanja bila ...odrediti fizičke i kemijske karakteristike terapijskog polja
visokofrekvencijskog generatora ozona.
U terapijskom polju je izmjeren spektar plazma elektrode u području 540-940 nm (atomske
linije Ne I i O I) dok se kod izboja kroz zrak bilježi i spektar mikro-izboja u području
290-440 nm (molekularne linije N2 i N2+). Na uzorku tkiva su izmjerene vrijednosti
efektivnog napona (22-95 mV), i efektivne struje (0,22-0,95 mA) na osnovu kojih su
procijenjene vrijednosti gustoće struje (4-19 μA/mm2) kao i snage (5-65 μW) te predane
energije u ovisnosti o vremenu izlaganja (0,14-10,75 mJ kod trajanja zahvata 30-
120 sekundi). Kod oba modaliteta primjene, u frekvencijskom području 33 kHz, zabilježena je
jakost magnetskog polja (1-3,07 A/m) i gustoće magnetskog toka (1,25-3,86 μT). Prilikom
pojave mikro-izboja u zračnom međuprostoru, u frekvencijskom području iznad 40 MHz, se
bilježi magnetsko polje jakosti (5-49 mA/m) te gustoće magnetskog toka od (6,5- 62,7 nT).
Jakost električnog polja na udaljenosti od 10 mm od elektrode iznosi 248-586 V/m. Tijekom
provedbe zahvata zabilježene su značajne promjene u temperaturi površine tkiva te one
ovisno o intenzitetu i trajanju zahvata (30-120 sek) iznose od 2.6 do 12,2°C. Statistička
analiza rezultata ukazala je na značajnu razliku u vrijednostima fizičkih veličinama s obzirom
na dva modaliteta primjene.
Na osnovu navedenih dokaza se zaključuje da djelovanje ispitivanog uređaja ne bi trebalo
pripisivati isključivo ozonu, kao što je to dosad bio slučaj, već kumulativnom učinku svih,
ovim istraživanjem dokazanih, fizičkih i kemijskih čimbenika koji su tijekom zahvata prisutni
u terapijskom polju.- A high-frequency ozone generator Ozonix (Biozonix GmbH, Germany) is classified as a
medical ozone generator, thus its therapeutic effects have, so far, been attributed exclusively
to ozone effect. The operative principle of the device and ozone production through a
dielectric barrier discharge using glass electrodes filled with a noble gas requires presence of
additional physical and chemical factors, besides ozone, in the treatment field during the
procedure. The purpose of the study was to determine the physical and chemical properties in
the treatment field of the said device. For that purpose, measuring of emission spectra, electric
and magnetic values as well as changes in surface temperature on tissue samples, as functions
of the selected intensity and exposure time, was conducted, and two basic application
modalities (contact discharge and air gap discharge) were used.
Materials and Methods: Optical emission spectroscopy was used to record the spectrum of a
plasma electrode’s glow discharge, a micro discharge occurring in the aerial interspace (air
gap) between the electrode and the targeted surface and the spectrum of the discharge through
a liquid medium on the surface of the tissue sample. By measuring electromagnetic values
present in the treatment field, physical values of electric and magnetic fields were recorded, as
well as currents passing through the treatment field. Thermographic measurements were used
to record temperature changes at different intensities (10-100%) and exposure durations (30,
60, 90 and 120 seconds).
Results: In the treatment field, two main emission spectra were recorded. Spectral lines of
plasma electrode’s glow discharge were recorded in the optical range between 540 and
940 nm, which were identified as atomic lines of neon (Ne I) and oxygen atoms (O I). This
spectrum is observed in all treatment modalities. During the formation of micro-discharges in
the air gap between the electrode and the treated surface, spectral lines were recorded in the
optical range between 290 and 440 nm, which were identified as molecular lines of N2 and N2+.
On the tissue samples (pork skin), as a function of output intensity (10-100%), electrical
values were recorded by use of oscilloscope and low impedance (Uin = 100) probe: RMS
voltage (22-95 mV), RMS current (0,22- 0.95 mA). These values were used to calculate
current density (4-19 μA/mm2) as well as power (5-65 μW). Using the same duration periods
as the ones used in the examination of temperature change at the tissue surface (30-120 sec),
the values of committed (delivered) energy were estimated (0,14-10,75 mJ).
Magnetic fields were recorded at two frequency ranges. In the frequency range of 33 kHz,
magnetic field was recorded in both treatment modalities as a function of intensity (10-100%)
for direct contact discharge H(1,93 ± 0,59 A/m), B (2,43 ± 0,75 μT), f (32151 ± 985Hz) and
air gap discharge H (2,5 ± 0,52 A/m), B (3,14 ± 0,65 μT), f (34526 ± 833 Hz). Only in the
case of micro-discharge formation in the air gap were additional peaks of magnetic field
observed in a wide frequency range from 40 to above 400 MHz. Due to the low intensity,
magnetic field values were calculated only for 41.5 MHz peak, where H field was
0,032 ± 0,014 A/m and B field was 40 ± 17,4 nT. At 10 mm distance from plasma electrode
surface, electric field strength was recorded in the range from 248 to 586 V/m depending on
the selected intensity (10-100%). During the treatment, a mild increase of temperature on the
surface of the tissue samples was recorded (2,6-12,2°C) as a function of intensity (20-100%)
and exposure time (30-120 seconds).
Conclusion: The results of the conducted research confirm the presence of mildly ionized
cold atmospheric plasma in the treatment field during air gap discharge. In both treatment
modalities, the presence of light in visible red and near infrared spectra, electric field,
magnetic fields, the currents flowing through the tissue and mild heat generated on the surface
of the tissue sample were confirmed in the treatment field. Furthermore, a significant
difference was determined in the values of physical properties with respect to the application
modality, where the values of temperature increase and magnetic field strengths are
significantly higher in the air gap modality whilst the values of electric current (and other
derived values) are lower compared to direct contact modality.
According to the results of this research, it can be concluded that treatment effects with the
tested devices must be attributed not only to ozone, but to cumulative effects of all physical
and chemical factors, the presence of which was recorded in the treatment field during this
research.- All metadata published by Europeana are available free of restriction under the Creative Commons CC0 1.0 Universal Public Domain Dedication. However, Europeana requests that you actively acknowledge and give attribution to all metadata sources including Europeana
Infracrvena termografija, odnosno termografija beskontaktna je metoda mjerenja energije zračenja. Mjerenjem energije zračenja indirektno se mjeri temperatura površine promatrane građevine, što ...omogućuje zaključivanje o statičkim i dinamičkim značajkama te građevine. Prikazane su mogućnosti primjene infracrvene termografije u građevinarstvu. Opisana je fizikalna osnova termografije, princip mjerne metode, rad termografskog uređaja te odgovarajuće norme, uz primjere primjene.
Termografija skrotuma je metoda dijagnostike varikokele. Postoji pet termografskih dijagnostičkih kriterija za dijagnozu
varikokele: termografski prikaz karakterističan za varikokelu, temperatura ...pampiniformnog pleksusa ≥34 C°, razlika temperature
između lijevog i desnog pampiniformnog pleksusa ≥0,5 C°, indikativna promjena slike prilikom Valsalvina manevra
i temperatura pampiniformnog pleksusa koja je ≥ temperaturi ipsilateralne natkoljenice. Tri ili više pozitivnih znakova predstavlja
pozitivan nalaz u slučaju dijagnostike varikokele. Cilj ovoga rada je prikazati primjenu termografije skrotuma kao
dijagnostičke metode u procjeni ishoda operacije varikokele. Prikazat ćemo slučaj studenta koji je imao dijagnozu varikokele
III. stupnja te je prijeoperacijski dijagnosticiran, a poslijeoperacijski praćen termografijom skrotuma. Prema termografskim
kriterijima ovaj bolesnik je prijeoperacijski imao varikokelu. Tri mjeseca nakon operacije bolesnik nije imao pozitivne termografske
znakove za varikokelu, međutim, klinički pregled i obojeni doppler nisu bilo tako uvjerljivi. Ovaj prikaz slučaja
pokazuje mogućnost primjene termografije skrotuma u praćenju bolesnika nakon operacije varikokele, no ovo svakako treba
potvrditi na većem broju ispitanika.
Rad prikazuje široke mogućnosti primjene infracrvene termografije u različitim područjima ljudske djelatnosti. U eksperimentalnom dijelu rada izvršeno je ispitivanje udobnosti nošenja odjevnog ...predmeta u kojem su ocjenjivači davali ocjene vezane uz vlažnost, toplinu i ukupnu udobnost prije umjerenog rada i nakon njega. Eksperiment je proveden pri ovim temperaturama: 23±1ºC, 26±1ºC, 29±1ºC i 32±1ºC i konstantnoj relativnoj vlažnosti zraka 67± 3%. Za određivanje zona pojačanog znojenja tijela upotrijebljene su fotografije ispitanika snimljene nakon izvršenog rada. Uočene zone uspoređene su s termografskim snimkama.
Iz rezultata subjektivnog ocjenjivanja topline, vlažnosti i udobnosti u tri uvjeta okoline vidljivo je smanjenje osjećaja udobnosti i povećanje osjećaja vlažnosti i topline s porastom temperature. Pri temperaturi 32 ºC apsorpcija znoja u materijalu trostruko je veća od apsorpcije na temperaturi 23 ºC. Uočene su i znatne razlike između intenziteta znojenja muških i ženskih ispitanika, pa je tako pri temperaturi 32 ºC apsorpcija znoja kod muških ispitanika 2,3 puta veća nego kod ženskih. Usporedbom područja na kojima je vidljivo nakupljanje znoja na majici s termografskom snimkom uočava se u tim zonama promjena temperature.
Energijsko certificiranje zgrada Mikulić, Dunja; Štirmer, Nina; Milovanović, Bojan ...
Građevinar,
12/2010, Volume:
62, Issue:
12.
Paper
Open access
U uvodnom dijelu se opisuje značenje energijskog certifikata za zgradu. Dalje su opisani osnovni zahtjevi Direktive 2010/31/EU o energijskom svojstvu zgrada te svrha i način izrade energijskog ...certifikata. Prikazani su osnovni elementi energijskog pregleda novih i postojećih zgrada u svrhu izrade energijskog certifikata. Opisane su najčešće metode mjerenja za utvrđivanju energijskog svojstva zgrade: mjerenje zrakopropusnosti (Blower Door Test) i uporaba infracrvene termografije.
Infracrvena termografija je metoda beskontaktnog mjerenja temperature i njezine raspodjele na površini promatranog objekta. Primjena termografije u zgradarstvu pruža velike mogućnosti kontrole ...kvalitete izvedbe kod novih građevina, ali i procjene trenutnog stanja starijih objekata. Osim što daje uvid u stanje objekta u smislu toplinske izolacije objekta, infracrvena termografija se može uspješno primijeniti za ocjenu stanja ovojnice građevine: otkrivanja različitih tipova grješaka (nedostataka i oštećenja) - otkrivanje mjesta odvajanja žbuke od podloge i mogućeg prisustva zraka ili vlage u slojevima ispod vanjske žbuke, te za procjenu stanja ravnih krovova - otkrivanje mjesta odvajanja sloja krovne ljepenke od podloge. Premda postoje različiti ograničavajući čimbenici kod termografskog snimanja građevinskih objekata, termografija se afirmirala kao metoda toplinske kontrole bez razaranja koja, u odnosu na neke druge metode nerazornog ispitivanja, posjeduje čitav niz prednosti. Između ostalog, metodom je omogućena trenutna analiza objekta na mjestu mjerenja kao i kontrola relativno velikih površina u kratkom vremenu, a naknadnom analizom moguća je i relativno jednostavna procjena kvalitete toplinske izolacije/toplinskih gubitaka objekta te otkrivanje strukture objekta ispod sloja žbuke. U radu su obrađeni primjeri detekcije različitih grešaka u području zgradarstva s osvrtom na zahtjeve norme HRN EN 13187. Obrađeni su slučajevi različitih stupnjeva oštećenja ovojnice zgrade, prisustvo vlage u zidovima objekta, toplinski mostovi i nekvalitetno brtvljenje, te prisustvo vlage i zraka u strukturi ravnog krova. U radu je posebno obrađeno mjerenje provedeno na upravnoj zgradi tvrtke Jadrolinija Rijeka, čiji je cilj bio utvrđivanje trenutnog stanja fasade i sukladno tomu davanje procjene o potrebi njezine sanacije. Za taj je slučaj, u sklopu analize termograma, provedena i numerička analiza prijenosa topline za karakteristične dijelove fasade sa i bez grešaka te su rezultati uspoređeni s rezultatima mjerenja.
Učinjen je termografski pregled 400 bolesnika s kliničkom dijagnozom ishialgije. Pregled je vršen nakon 15 minuta hlađenja na ambijentnoj temperaturi od 18—21°C aparatom AGA 780 Medical. U 376 ...bolesnika nađena je hipotermija, a u 5 hipertermija iznad oboljelog ekstremiteta. 6 bolesnika imalo je simetričnu izotermnu distribuciju, a u 13 bolesnika bilo kakav zaključak je bio nesiguran zbog obilja varikoznih vena na nogama. Termografske promjene na nogama su imale različite lokalizacije. Termografske promjene iznad lumbalne kralješnice bile su uglavnom na suprotnoj strani od promjena na nogama i bile su u vidu hipertermije, ali siguran zaključak bio je moguć u samo 57 % oboljelih. Tako termografija omogućava dijagnostiku ishialgije pokazujući promjene iznad oboljelog ekstremiteta u gotovo svih bolesnika s aktualnim smetnjama.
Mada postoje općeprihvaćeni dijagnostički kriteriji za hondromalaciju patele, bolest često prate simptomi koji nisu dostatni ili su od male dijagnostičke vrijednosti. Vrlo je lako previdjeti ili, ...pak, dijagnosticirati prevelik broj takvih bolesnika. Pozitivna artroskopija (ili artrografija) ne znači da je uzrok boli hondromalacija, a potpuno karakteristične kliničke nalaze može pratiti potpuno uredan (negativan) artroskopski nalaz. U našem prethodnom radu izvijestili smo o termografskim promjenama u bolesnika s hondromalacijom patele. Sada iznosimo podatke za 308 zdravih osoba, 157 novih osoba, s kliničkom dijagnozom hondromalacije, i 15 osoba koje su duže vremena imale tegobe iza operacije, koja je učinjena zbog hondromalacije. Našli smo da je osjetljivost metode 69%, specifičnost 79,5% ( s tim da je ovisna o dobi i varira od 65% u odraslih do 89,7% u mladih). 19,6% zdravih osoba ima iste termograme kao bolesnici s hondromalacijom. U 92% operiranih bolesnika termogram potvrđuje prisustvo tegoba, pokazujući odstupanja od nalaza koji vidimo u zdravih, odnosno onih osoba koje nemaju iza operacije tegoba. Termogram je od velike pomoći u dijagnostici hondromalacije patele u mladih osoba, ali nije dovoljno specifičan za tu dijagnozu u odraslih.