The effect of nitrogen-ion implantation on the corrosion resistance of titanium in comparison with oxygen- and argon-ion implantationsSundararajan, T. ; Praunseis, ZdravkoCommercially pure (CP) titanium was surface modified with nitrogen-, argon- and oxygen-ion implantations in order to investigate the material's corrosion resistance in a simulated body fluid. Five ... doses were chosen for the ions, ranging from 5.1015 cm-2 to 2.5-1017 cm-2. In-vitro open-cyclic potential-timemeasurements and cyclic polarization studies were carried out to evaluate the corrosion resistance of the modified surface in comparison to an unmodified surface. Specimens implanted at 4.1016 cm-2 and 7.1016 cm-2 showed the optimum corrosion resistance, higher doses showed a detrimental effect on the corrosion resistance. Argon- and oxygen-ion implantation at these doses did not show any improved corrosion resistance, indicating the beneficial role of nitrogen on the corrosion resistance of titanium in the simulated body-fluid environment. Grazing-incidence X-ray diffraction (GIXD) was employed on the implanted specimens to determine the phases formed with the increasing doses. X-ray photoelectron spectroscopy (XPS) studies on the passive film of the implanted samples and on the unimplanted samples were analyzed in order to understand the role of nitrogen in improving the corrosion resistance. The results of the present investigation indicated that nitrogen-ion implantation can be used as a viable method for improving the corrosion resistance of titanium. The nature of the surface and the reason for the variation and the improvement in the corrosion resistance are discussed in detail.Source: Materiali in tehnologije = Materials and technology. - ISSN 1580-2949 (Letn. 38, št. 1/2, 2004, str. 19-24)Type of material - article, component partPublish date - 2004Language - englishCOBISS.SI-ID - 8767254
Author
Sundararajan, T. |
Praunseis, Zdravko
Topics
metalurgija |
ionska implantacija |
ortopedski implantati |
korozija |
titan |
dušik |
kisik |
argon |
metallurgy |
ion implantation |
orthopedic implants |
corrosion |
titanium |
nitrogen |
oxygen |
argon
source: Materiali in tehnologije = Materials and technology. - ISSN 1580-2949 (Letn. 38, št. 1/2, 2004, str. 19-24)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|---|
Sundararajan, T. | |
Praunseis, Zdravko | 08488 |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
Pickup location | Material status | Reservation |
---|
Please wait a moment.